Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Research Protocols

Date Submitted: Jan 3, 2018
Open Peer Review Period: Jan 5, 2018 - Jan 19, 2018
Date Accepted: Feb 23, 2018
(closed for review but you can still tweet)

The final, peer-reviewed published version of this preprint can be found here:

Exploring the Waveform Characteristics of Tidal Breathing Carbon Dioxide, Measured Using the N-Tidal C Device in Different Breathing Conditions (The General Breathing Record Study): Protocol for an Observational, Longitudinal Study

Neville DM, Rupani H, Kalra PR, Adeniji K, Quint M, De Vos R, Begum S, Mottershaw M, Fogg C, Jones TL, Lanning E, Bassett P, Chauhan AJ

Exploring the Waveform Characteristics of Tidal Breathing Carbon Dioxide, Measured Using the N-Tidal C Device in Different Breathing Conditions (The General Breathing Record Study): Protocol for an Observational, Longitudinal Study

JMIR Res Protoc 2018;7(5):e140

DOI: 10.2196/resprot.9767

PMID: 29798833

PMCID: 5992452

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Exploring the Waveform Characteristics of Tidal Breathing Carbon Dioxide, Measured Using the N-Tidal C Device in Different Breathing Conditions (The General Breathing Record Study): Protocol for an Observational, Longitudinal Study

  • Daniel M Neville; 
  • Hitasha Rupani; 
  • Paul R Kalra; 
  • Kayode Adeniji; 
  • Matthew Quint; 
  • Ruth De Vos; 
  • Selina Begum; 
  • Mark Mottershaw; 
  • Carole Fogg; 
  • Thomas L Jones; 
  • Eleanor Lanning; 
  • Paul Bassett; 
  • Anoop J Chauhan

Background:

In an increasingly comorbid population, there are significant challenges to diagnosing the cause of breathlessness, and once diagnosed, considerable difficulty in detecting deterioration early enough to provide effective intervention. The burden of the breathless patient on the health care economy is substantial, with asthma, chronic heart failure, and pneumonia affecting over 6 million people in the United Kingdom alone. Furthermore, these patients often have more than one contributory factor to their breathlessness symptoms, with conditions such as dysfunctional breathing pattern disorders—an under-recognized component. Current methods of diagnosing and monitoring breathless conditions can be extensive and difficult to perform. As a consequence, home monitoring is poorly complied with. In contrast, capnography (the measurement of tidal breath carbon dioxide) is performed during normal breathing. There is a need for a simple, easy-to-use, personal device that can aid in the diagnosis and monitoring of respiratory and cardiac causes of breathlessness.

Objective:

The aim of this study was to explore the use of a new, handheld capnometer (called the N-Tidal C) in different conditions that cause breathlessness. We will study whether the tidal breath carbon dioxide (TBCO2) waveform, as measured by the N-Tidal C, has different characteristics in a range of respiratory and cardiac conditions.

Methods:

We will perform a longitudinal, observational study of the TBCO2 waveform (capnogram) as measured by the N-Tidal C capnometer. Participants with a confirmed diagnosis of asthma, breathing pattern disorders, chronic heart failure, motor neurone disease, pneumonia, as well as volunteers with no history of lung disease will be asked to provide twice daily, 75-second TBCO2 collection via the N-Tidal C device for 6 months duration. The collated capnograms will be correlated with the underlying diagnosis and disease state (stable or exacerbation) to determine if there are different TBCO2 characteristics that can distinguish different respiratory and cardiac causes of breathlessness.

Results:

This study’s recruitment is ongoing. It is anticipated that the results will be available in late 2018.

Conclusions:

The General Breathing Record Study will provide an evaluation of the use of capnography as a diagnostic and home-monitoring tool for various diseases.

International Registered Report:

RR1-10.2196/9767


 Citation

Please cite as:

Neville DM, Rupani H, Kalra PR, Adeniji K, Quint M, De Vos R, Begum S, Mottershaw M, Fogg C, Jones TL, Lanning E, Bassett P, Chauhan AJ

Exploring the Waveform Characteristics of Tidal Breathing Carbon Dioxide, Measured Using the N-Tidal C Device in Different Breathing Conditions (The General Breathing Record Study): Protocol for an Observational, Longitudinal Study

JMIR Res Protoc 2018;7(5):e140

DOI: 10.2196/resprot.9767

PMID: 29798833

PMCID: 5992452

Per the author's request the PDF is not available.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.