Previously submitted to: JMIR Medical Informatics (no longer under consideration since Apr 20, 2026)
Date Submitted: Apr 3, 2026
Open Peer Review Period: Apr 20, 2026 - Apr 20, 2026
(closed for review but you can still tweet)
NOTE: This is an unreviewed Preprint
Warning: This is a unreviewed preprint (What is a preprint?). Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn (a note "no longer under consideration" will appear above).
Peer review me: Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period (in this case, a "Peer Review Me" button to sign up as reviewer is displayed above). All preprints currently open for review are listed here. Outside of the formal open peer-review period we encourage you to tweet about the preprint.
Citation: Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author).
Final version: If our system detects a final peer-reviewed "version of record" (VoR) published in any journal, a link to that VoR will appear below. Readers are then encourage to cite the VoR instead of this preprint.
Settings: If you are the author, you can login and change the preprint display settings, but the preprint URL/DOI is supposed to be stable and citable, so it should not be removed once posted.
Submit: To post your own preprint, simply submit to any JMIR journal, and choose the appropriate settings to expose your submitted version as preprint.
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
A Risk-Aware Adaptive Screening Framework for Psychiatric Assessment: Development and Validation Study
ABSTRACT
Background:
Psychiatric outpatient assessment commonly requires patients to complete a large battery of self-report scales. A real-world outpatient receipt collected for this study documented 14 scales, a total fee of CNY 610, and an estimated completion time of 2 to 3 hours. Existing approaches — including fixed scale packages and computerized adaptive testing — either lack personalization or require extensive parametric calibration poorly suited to multidimensional psychiatric symptom spectra.
Objective:
This study aimed to develop and evaluate the Risk-Aware Adaptive Screening (RAAS) framework, a hybrid system integrating a clinical rule engine, a gradient boosting classifier, and an adaptive confidence switching mechanism to reduce unnecessary questionnaire burden while maintaining clinical safety, operationalized as non-omission of genuine assessment needs.
Methods:
We conducted a retrospective modeling study using the publicly available DASS-42 dataset (n=39,764). Labels for depression, anxiety, and stress dimensions were derived using the 60th-percentile threshold on summed item scores, exceeding the DASS official moderate-severity lower bounds (indicating positive labels correspond to moderate-to-severe symptomatology). The two-stage RAAS framework first applies a rule engine (signal-item mean threshold τ=1.2), then a LightGBM multi-label classifier. An adaptive confidence mechanism (θ=0.75) determines the involvement of each stage. The primary safety metric was Recall@K (proportion of genuinely needed dimensions correctly recommended). Five baselines were compared, including logistic regression, random forest, and GBM-only configurations. Statistical stability was assessed with bootstrap resampling (n=2,000). Threshold sensitivity analysis swept θ across [0.50, 1.00].
Results:
The proposed adaptive Rule+GBM method reduced the average number of recommended dimensions from 3.00 to 1.15 (reduction rate 61.7%) while achieving Recall@K=0.989 (95% CI 0.987-0.991). Recall@K remained stable at 0.989 across θ ∈ [0.50, 0.80]. Signal item ablation confirmed that safety performance is driven by the GBM classifier, not by expert signal item selection (difference <0.1 percentage points). The rule engine does not change recommendations in 99.8% of low-confidence cases; its value is providing semantically grounded reasoning pathways for clinician review.
Conclusions:
The RAAS framework reduced questionnaire burden by 61.7% while maintaining near-complete clinical recall, matching the safety of a pure machine learning approach while providing interpretable reasoning for low-confidence cases. Future work should validate the framework prospectively in real clinical settings and extend it to broader psychiatric symptom spectra.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.