Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Formative Research

Date Submitted: Dec 1, 2025
Date Accepted: Aug 31, 2026

The final, peer-reviewed published version of this preprint can be found here:

Enhancing a Behavioral Intervention Using Rest-Activity Rhythm Monitoring via a Consumer Wearable in Older Dementia Caregivers and People With Dementia: Feasibility and Acceptability Study

Stahl S, Rodakowski J, Patira R, Smagula S

Enhancing a Behavioral Intervention Using Rest-Activity Rhythm Monitoring via a Consumer Wearable in Older Dementia Caregivers and People With Dementia: Feasibility and Acceptability Study

JMIR Form Res 2026;10:e88773

DOI: 10.2196/88773

PMID: 42815039

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Enhancing a behavioral intervention for older adults with rest/activity rhythm monitoring via a consumer wearable

  • Sarah Stahl; 
  • Juleen Rodakowski; 
  • Riddhi Patira; 
  • Stephen Smagula

ABSTRACT

Despite being an established risk factor for poor mental/brain health outcomes in aging, rest/activity rhythm (RAR) disturbances are not routinely monitored/treated. This is, in part, due to a lack of clinician-friendly RAR monitoring systems. We tested the feasibility of personalizing a six-week behavioral intervention using RAR monitoring from a consumer-wearable device (Apple Watch). Participants were 21 older adults (15 dementia caregivers (mean age=61.8 years, standard deviation (SD)=8.4) and 6 people with dementia (PWD; mean age=81.45 years, SD=8.5)). Feasibility outcomes were: (a) proportion adherent enough to assess RARs (defined as ≥3 consecutive valid days with ≥20 hours/per day); and (b) the total number of valid days. All 21 participants obtained the minimum data requirement for measuring RARs. Caregivers averaged 35 valid days and 15/15 were actively monitoring RARs during week six of the trial. In contrast, PWD averaged 30 valid days, and only 2/6 were active at the trial’s end. In 11 caregivers with pre/post measures, we evaluated changes in depression (Patient Health Questionnaire – 9) and insomnia (Insomnia Severity Index) symptoms. There were medium effect size improvements in depression (Hedges’ g=0.67, 95% confidence interval (CI): 0.04-1.28) and large improvements in insomnia (Hedges’ g=0.94, 95% CI: 0.25-1.61) symptoms. These findings show older adults without dementia were highly engaged with RAR monitoring, supporting the feasibility of personalizing interventions with RAR monitoring, and RCTs testing if RAR monitoring improves intervention efficiency/efficacy. Measuring RARs with a consumer wearable is possible in PWD, but lower usage indicates there are barriers to longer-term adherence in this group.


 Citation

Please cite as:

Stahl S, Rodakowski J, Patira R, Smagula S

Enhancing a Behavioral Intervention Using Rest-Activity Rhythm Monitoring via a Consumer Wearable in Older Dementia Caregivers and People With Dementia: Feasibility and Acceptability Study

JMIR Form Res 2026;10:e88773

DOI: 10.2196/88773

PMID: 42815039

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.