Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Research Protocols

Date Submitted: Aug 24, 2025
Date Accepted: Jan 19, 2026
Date Submitted to PubMed: Jan 20, 2026

The final, peer-reviewed published version of this preprint can be found here:

Clinical Evaluation of Pediatric Pulse Oximeters in South Africa: Protocol for a Cluster Randomized Controlled Trial

Schuh HB, Van der Zalm M, Van Niekerk M, Laubscher LM, Mcinziba A, Gomas S, Kapoor S, Hooli S, Viljoen L, Gie A, Nonyane BA, Goussard P, Hesseling AC, King C, McCollum ED

Clinical Evaluation of Pediatric Pulse Oximeters in South Africa: Protocol for a Cluster Randomized Controlled Trial

JMIR Res Protoc 2026;15:e82888

DOI: 10.2196/82888

PMID: 41555185

Clinical evaluation of pediatric pulse oximeters in South Africa: cluster randomized controlled trial protocol

  • Holly B Schuh; 
  • Marieke Van der Zalm; 
  • Margaret Van Niekerk; 
  • Lise-Marie Laubscher; 
  • Abenathi Mcinziba; 
  • Steve Gomas; 
  • Sunaina Kapoor; 
  • Shubhada Hooli; 
  • Lario Viljoen; 
  • Andre Gie; 
  • Bareng A.S. Nonyane; 
  • Pierre Goussard; 
  • Anneke C. Hesseling; 
  • Carina King; 
  • Eric D. McCollum

ABSTRACT

Background:

The burden of young children with lower respiratory infections and low blood oxygen levels (hypoxemia) is high and outcomes are generally poor, especially in low-and-middle-income countries (LMICs). Pulse oximeter devices non-invasively measure the capillary oxyhemoglobin saturation (SpO2) to identify hypoxemia, but high-quality devices designed for the unique needs of children are rarely available in primary healthcare clinics (PHCs) in LMICs where children initially access care.

Objective:

To evaluate whether two pediatric pulse oximeters co-designed with healthcare workers (HCWs) in LMICs, compared to a standard pulse oximeter, improve the correct SpO2 management of children in PHCs.

Methods:

We are conducting a pragmatic three-arm cluster randomized controlled trial in the Eastern Khayelitsha, Northern, and Tygerberg areas of Cape Town, South Africa, over 18 months between 2024-2026. We plan to enroll 1,200 children <2-years-old with an acute respiratory infection from 18 PHCs randomized to implement one of three pulse oximeters, either one standard of care device or two intervention devices. HCWs working in eligible and selected PHCs will administer the trial intervention. Our primary outcome will be ‘correct SpO2 management,’ defined as (1) a HCW-documented SpO2 and heart rate measured in room air, (2) an appropriate referral recommendation provided by the HCW, and (3) a SpO2 confirmed by a successful study staff measurement with reference device that is within a 2% SpO2 range above or below the HCW documented SpO2. A concurrent mixed methods process evaluation will explore how, why, for whom, and to what extent these pediatric pulse oximetry devices impact the clinical management of hypoxemic children. The primary analysis will be an intention to treat analysis, and for all primary and secondary outcomes, we will conduct pairwise comparisons between the two intervention device arms and the control arm.

Results:

The study was funded in 2023 with data collection commencing in late 2024. Results are expected to be published in 2026-2027.

Conclusions:

While there are notable challenges inherent to the design of a trial aiming to evaluate whether pulse oximeters improve HCW SpO2 management of young children accessing care in PHCs, our protocol development process attempted to adequately address all potential limitations and sources of bias with the goal of maximizing the trial’s future impact. Clinical Trial: Clinicaltrials.gov (NCT05914324).


 Citation

Please cite as:

Schuh HB, Van der Zalm M, Van Niekerk M, Laubscher LM, Mcinziba A, Gomas S, Kapoor S, Hooli S, Viljoen L, Gie A, Nonyane BA, Goussard P, Hesseling AC, King C, McCollum ED

Clinical Evaluation of Pediatric Pulse Oximeters in South Africa: Protocol for a Cluster Randomized Controlled Trial

JMIR Res Protoc 2026;15:e82888

DOI: 10.2196/82888

PMID: 41555185

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.