Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR AI

Date Submitted: Jul 29, 2025
Date Accepted: Sep 8, 2026

The final, peer-reviewed published version of this preprint can be found here:

Quality Assessment and Model Training Impact of Synthetic Images in Medical Diagnostic Imaging: Systematic Review

Folguera-Profitós J, Ramiro-Pareta M, Carot-Sans G, Jiménez-Rueda A, Aznar-Roig J, Domínguez-Herrera D, Nogueras MM, Nadimi E, Torres F, Piera-Jiménez J

Quality Assessment and Model Training Impact of Synthetic Images in Medical Diagnostic Imaging: Systematic Review

JMIR AI 2026;5:e81472

DOI: 10.2196/81472

PMID: 42879762

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Synthetic images in diagnostic imaging: a systematic review of quality assessment and model training impact

  • Júlia Folguera-Profitós; 
  • Marina Ramiro-Pareta; 
  • Gerard Carot-Sans; 
  • Alba Jiménez-Rueda; 
  • Júlia Aznar-Roig; 
  • Didier Domínguez-Herrera; 
  • Maria Mercedes Nogueras; 
  • Esmaeil Nadimi; 
  • Ferran Torres; 
  • Jordi Piera-Jiménez

ABSTRACT

Background:

The use of artificial intelligence (AI) to generate synthetic images has been increasingly used to overcome the scarcity of large, regulatory-compliant medical images datasets. However, their quality and actual utility in algorithm development across deep learning architectures, medical settings, and image type has been poorly assessed.

Objective:

To revise the use of synthetic images for algorithm development and assess their quality and effect on downstream algorithms trained with these images, according to AI architecture, medical setting, and image type.

Methods:

We conducted a systematic review following PRISMA guidelines. PubMed was searched in January 2024 using terms related to synthetic image generation, diagnostic imaging, and model evaluation, restricted to January 2020-December 2023. Eligible studies evaluated diagnostic, or follow-up applications incorporating synthetic images, reported quantitative measures of image quality or model performance, used human imaging data, and were published as full-text English articles. Studies using synthetic images for non-diagnostic purposes, microscopic/histopathology imaging, and non-primary literature were excluded. Two independent reviewers conducted study selection with discrepancies resolved through group discussion. Data extraction focused on generative architectures, image quality metrics (fidelity, perceptual, Turing-style, distribution-alignment), and downstream model performance outcomes. Risk of bias was assessed using custom criteria based on reporting guidelines for observational studies. Due to insufficient variance reporting across studies, only descriptive analyses (and not pooled analyses) were conducted.

Results:

From 952 articles identified, 94 studies met inclusion criteria. MRI, X-ray, and CT were the predominant imaging modalities (representing the majority of studies), primarily applied in oncology, respiratory diseases, and neurology. GAN-based architectures dominated synthetic image generation (83% of studies). Among 49 distinct quality metrics identified, Turing-style realism metrics were most frequently used, followed by perceptual and fidelity metrics. Seventy-six studies evaluated downstream model performance, revealing that training exclusively on synthetic images often resulted in performance decrements, particularly for segmentation tasks (declining Dice scores). In contrast, augmenting original datasets with synthetic images showed more consistent improvements, especially for classification metrics across most imaging modalities. Risk of bias assessment revealed significant methodological concerns, with only 22% of studies rated as low risk; primary sources of bias included inadequate reporting of sampling strategies, population characteristics, and lack of measures of variance/confidence.

Conclusions:

Synthetic images show promise for addressing dataset limitations in medical AI, but current evidence demonstrates substantial methodological heterogeneity and modest performance improvements that limit clinical translation. The field urgently requires standardized evaluation frameworks and consensus reporting guidelines. Future research should prioritize developing robust, clinically validated frameworks to guide responsible deployment of synthetic image-enhanced AI systems in healthcare. Clinical Trial: PROSPERO (CRD42023369125).


 Citation

Please cite as:

Folguera-Profitós J, Ramiro-Pareta M, Carot-Sans G, Jiménez-Rueda A, Aznar-Roig J, Domínguez-Herrera D, Nogueras MM, Nadimi E, Torres F, Piera-Jiménez J

Quality Assessment and Model Training Impact of Synthetic Images in Medical Diagnostic Imaging: Systematic Review

JMIR AI 2026;5:e81472

DOI: 10.2196/81472

PMID: 42879762

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.