Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Human Factors

Date Submitted: Apr 3, 2025
Date Accepted: Dec 1, 2025

The final, peer-reviewed published version of this preprint can be found here:

Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study

Shah P, Sy S, Chen M, Khoo MC, Coates TD, Veluswamy S

Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study

JMIR Hum Factors 2026;13:e75465

DOI: 10.2196/75465

PMID: 41494152

PMCID: 12775748

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Wearable Device Photoplethysmography is a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-occlusive Crisis in Sickle Cell Disease

  • Payal Shah; 
  • Sabrina Sy; 
  • Mingjing Chen; 
  • Michael C.K. Khoo; 
  • Thomas D. Coates; 
  • Saranya Veluswamy

ABSTRACT

Background:

Entrapment of sickled red blood cells in the microvasculature leads to sudden painful vaso-occlusive crises (VOC) in sickle cell disease (SCD). This is potentially triggered by autonomic nervous system mediated vasoconstriction in peripheral vasculature and resultant decrease in microvascular blood flow. Indeed, vasoconstriction biomarkers derived from a single night of laboratory-based fingertip photoplethysmography (PPG) recording were predictive of higher frequency of future VOC in SCD. Non-invasive, remote and longitudinal monitoring of autonomic vasoreactivity will facilitate development of predictive biomarkers of imminent VOC.

Objective:

To assess the feasibility and performance of wearable wristband device to longitudinally monitor nocturnal peripheral autonomic vasoreactivity and to cross-validate the vasoconstriction parameters across the “gold-standard” finger sensor.

Methods:

11 subjects with SCD and 5 healthy controls were recruited to wear a wristband device (Biostrap) with PPG sensor on a nightly basis. For cross-validation studies, 3 subjects wore both the wristband and a sleep monitoring device (AliceNightOne) with finger PPG sensor. We quantified autonomic vasoreactivity by processing PPG signals and deriving vasoconstriction parameters - magnitude of vasoconstriction (Mvasoc) and Coefficient of Variation (PPGampCV). We performed correlation analysis of the vasoconstriction parameters within each device to investigate if Mvasoc and PPGamp CV can be surrogate markers of vasoconstriction and then cross-validated the PPGampCV across the wristband and finger PPG devices.

Results:

A total of 115 nocturnal PPG recordings were made with wristband device (1-19 nights/subject; SCD=70, controls=45). A total of 9 nocturnal recordings (3 nights/subject) were made with both wristband and finger sensor devices. Longitudinal continuous PPG recordings were feasible with wearable devices with subjects reporting ease of use. There was significant within night and night-to-night variability in vasoconstriction parameters suggesting dynamic changes in autonomic vasoreactivity. Mvasoc and PPGampCV significantly correlated within devices - the maximum overnight correlation was 0.82 (P<.001) for finger sensor and 0.69 (P <.001) for wristband sensor, suggesting that PPGampCV can serve as a surrogate for Mvasoc. Cross-validation analysis of PPGampCV across wristband and fingertip sensors showed statistically significant correlation across all nights (overnight correlation coefficient ranging from 0.24-0.7) with some nightly segments of PPGampCV showing near perfect correlation between devices.

Conclusions:

Wearable wristband devices are feasible tools for collection of continuous PPG measurements and vasoconstriction parameters, which serve as objective markers of autonomic vasoreactivity in subjects with and without SCD. We have optimized the methods of quantifying vasoconstriction from wearable device PPG signals, while minimizing effects of artefacts and cross-validated them with standardized sensors. These findings enable large scale, real-time monitoring of autonomic vasoreactivity along with pain outcomes for the development of vasoconstriction parameters as a biomarker of imminent VOC in SCD. This biomarker has potential to impact not only SCD but also other diseases involving autonomic vascular dysregulation.


 Citation

Please cite as:

Shah P, Sy S, Chen M, Khoo MC, Coates TD, Veluswamy S

Wearable Device Photoplethysmography As a Viable Tool to Longitudinally Monitor Vasoconstriction Biomarkers for Predicting Vaso-Occlusive Crisis in Sickle Cell Disease: Feasibility and Validation Study

JMIR Hum Factors 2026;13:e75465

DOI: 10.2196/75465

PMID: 41494152

PMCID: 12775748

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.