Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Medical Informatics

Date Submitted: Aug 20, 2024
Date Accepted: Dec 8, 2025

The final, peer-reviewed published version of this preprint can be found here:

Effects of Image Degradation on Deep Neural Network Classification of Scaphoid Fracture Radiographs: Comparison Study of Different Noise Types

Lin C, Yoon AP, Wang CW, Chung KC, Kuo CF

Effects of Image Degradation on Deep Neural Network Classification of Scaphoid Fracture Radiographs: Comparison Study of Different Noise Types

JMIR Med Inform 2026;14:e65596

DOI: 10.2196/65596

PMID: 41570307

PMCID: 12826633

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Effects of Image Degradation on Deep Neural Network Classification of Scaphoid Fracture Radiographs

  • Chihung Lin; 
  • Alfred P. Yoon; 
  • Chien-Wei Wang; 
  • Kevin C. Chung; 
  • Chang-Fu Kuo

ABSTRACT

This study evaluated the performance of a deep learning model trained to detect scaphoid fractures in radiographs when various perturbations were added to the images. The datasets were modified by applying Gaussian noise; via blurring, JPEG compression, contrast-limited adaptive histogram equalization (CLAHE), and resizing; and the addition of geometric offsets. Model accuracy declined as the severity of perturbations increased; however, the extent of performance decline varied according to the type of perturbation. The model demonstrated greater resistance to color perturbations than to grayscale perturbations, but the application of Gaussian blur exerted a considerably negative impact on model performance. CLAHE increased the false-positive rate. There was a strong linear relationship between image quality and model performance; the model performed better on higher-quality images. We also found that geometric offset or pixel value rescaling did not affect the performance of the deep learning model. Resolution was the most significant factor influencing model performance; localizing the region of interest may minimize any decrease in accuracy. Overall, this study provides insights into the robustness of deep learning models that detect small fractures, such as scaphoid fractures, in radiographs subjected to various perturbations. The findings could guide the development of more accurate models for medical image analysis. The cumulative insights gained from this study will contribute to the design of more accurate and robust deep learning models tailored for medical image analysis, especially under conditions of varying image quality.


 Citation

Please cite as:

Lin C, Yoon AP, Wang CW, Chung KC, Kuo CF

Effects of Image Degradation on Deep Neural Network Classification of Scaphoid Fracture Radiographs: Comparison Study of Different Noise Types

JMIR Med Inform 2026;14:e65596

DOI: 10.2196/65596

PMID: 41570307

PMCID: 12826633

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.