Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Biomedical Engineering

Date Submitted: Jun 6, 2024
Date Accepted: Jun 6, 2025

The final, peer-reviewed published version of this preprint can be found here:

Estimation of Brachial-Ankle Pulse Wave Velocity With Hierarchical Regression Model From Wrist Photoplethysmography and Electrocardiographic Signals: Method Design

Ho CI, Yen CH, Li YC, Huang CH, Guo JW, Tsai PY, Lin HJ, Wang TD

Estimation of Brachial-Ankle Pulse Wave Velocity With Hierarchical Regression Model From Wrist Photoplethysmography and Electrocardiographic Signals: Method Design

JMIR Biomed Eng 2025;10:e58756

DOI: 10.2196/58756

PMID: 40931883

PMCID: 12423722

Estimation of Brachial-Ankle Pulse Wave Velocity with Hierarchical Regression Model from Wrist Photoplethysmography and Electrocardiographic Signals: Method Design

  • Chih-I Ho; 
  • Chia-Hsiang Yen; 
  • Yu-Chuan Li; 
  • Chiu-Hua Huang; 
  • Jia-Wei Guo; 
  • Pei-Yun Tsai; 
  • Hung-Ju Lin; 
  • Tzung-Dau Wang

ABSTRACT

Background:

Photoplethysmography (PPG) signals captured by wearable devices can provide vascular information and support pervasive and long-term monitoring of personal health condition.

Objective:

In this study, we aimed to estimate brachial-ankle pulse wave velocity (baPWV) from wrist PPG and electrocardiography (ECG) from smart watch.

Methods:

A total of 914 wrist PPG and ECG sequences and 278 baPWV measurements were collected via the smart watch from 80 men and 82 women with average age of 63.4 ± 13.4 and 64.3 ± 11.6 years. Feature extraction and weighted pulse decomposition were applied to identify morphological characteristics regarding blood volume change and component waves in pre-processed PPG and ECG signals. A systematic strategy of feature combination was performed. The hierarchical regression method based on the random forest for classification and extreme gradient boosting (XGBoost) algorithms for regression was employed, which first classified the data into subdivisions. The respective regression model for the subdivision was constructed with an overlapping zone.

Results:

By using 914 sets of wrist PPG and ECG signals for baPWV estimation, the hierarchical regression model with 2 subdivisions and an overlapping zone of 400 cm/s achieved root mean square error (RMSE) of 145.0 cm/s and 141.4 cm/s for 24 men and 26 women, respectively, which is better than the general XGBoost regression model and the multivariable regression model.

Conclusions:

We for the first time demonstrated that baPWV could be reliably estimated by the wrist PPG and ECG signals measured by the wearable device. Whether our algorithm could be applied clinically needs further verification. Clinical Trial: Research ethics committee of National Taiwan University Hospital (No. 201902087RIPA)


 Citation

Please cite as:

Ho CI, Yen CH, Li YC, Huang CH, Guo JW, Tsai PY, Lin HJ, Wang TD

Estimation of Brachial-Ankle Pulse Wave Velocity With Hierarchical Regression Model From Wrist Photoplethysmography and Electrocardiographic Signals: Method Design

JMIR Biomed Eng 2025;10:e58756

DOI: 10.2196/58756

PMID: 40931883

PMCID: 12423722

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.