Accuracy, Usability, and Adherence of Smartwatches for Atrial Fibrillation Detection in Older Adults After Stroke: Randomized Controlled Trial

Ding EY, Tran KV, Lessard D, Wang Z, Han D, Mohagheghian F, Mensah Otabil E, Noorishirazi K, Mehawej J, Filippaios A, Naeem S, Gottbrecht MF, Fitzgibbons TP, Saczynski JS, Barton B, Chon K, McManus DD

Accuracy, Usability, and Adherence of Smartwatches for Atrial Fibrillation Detection in Older Adults After Stroke: Randomized Controlled Trial

JMIR Cardio 2023;7:e45137

DOI: 10.2196/45137

PMID: 38015598

PMCID: 10716742

Accuracy, Usability, and Adherence of Smartwatches for Atrial Fibrillation Detection in Older Adults After Stroke: the Pulsewatch Randomized Controlled Trial

  • Eric Y. Ding; 
  • Khanh-Van Tran; 
  • Darleen Lessard; 
  • Ziyue Wang; 
  • Dong Han; 
  • Fahimeh Mohagheghian; 
  • Edith Mensah Otabil; 
  • Kamran Noorishirazi; 
  • Jordy Mehawej; 
  • Andreas Filippaios; 
  • Syed Naeem; 
  • Matthew F. Gottbrecht; 
  • Timothy P. Fitzgibbons; 
  • Jane S. Saczynski; 
  • Bruce Barton; 
  • Ki Chon; 
  • David D. McManus

ABSTRACT

Background:

Atrial fibrillation (AF) is a common cause of stroke and timely diagnosis is critical for secondary prevention. Little is known about smartwatches for AF detection among stroke survivors.

Objective:

We aimed to examine accuracy, usability, and adherence to a smartwatch-based AF monitoring system designed by older stroke survivors and their caregivers.

Methods:

Pulsewatch is a randomized-controlled trial in which stroke survivors received either a smartwatch-smartphone dyad for AF detection (Pulsewatch system) plus an ECG patch or the patch alone for 14 days to assess accuracy and usability of the system (Phase I). Participants were subsequently re-randomized to potentially 30 additional days of system use to examine adherence to watch wear (Phase II). Participants were at least 50-years-old, survived an ischemic stroke, and had no major contraindications to oral anticoagulants. Accuracy for AF detection was determined by comparing to cardiologist-overread ECG patch, and usability was assessed with the System Usability Scale. Adherence was operationalized as daily watch wear time over the 30-day monitoring period.

Results:

120 participants were enrolled (mean age 65, 41% female, 87% white). The Pulsewatch system demonstrated 92.9% accuracy (95% confidence interval: 85.3%–97.4%) for AF detection. Mean usability score was 65/100 and on average, participants wore the watch on 21.2 (SD 8.3) of 30 days.

Conclusions:

Our findings demonstrate that a smartwatch system designed by and for stroke survivors is a viable option for long term arrhythmia detection among older adults at risk for atrial fibrillation, though it may benefit from strategies to enhance adherence to watch wear. Clinical Trial: clinicaltrials.gov registration number NCT03761394 (https://www.clinicaltrials.gov/ct2/show/NCT03761394)


 Citation

Please cite as:

Ding EY, Tran KV, Lessard D, Wang Z, Han D, Mohagheghian F, Mensah Otabil E, Noorishirazi K, Mehawej J, Filippaios A, Naeem S, Gottbrecht MF, Fitzgibbons TP, Saczynski JS, Barton B, Chon K, McManus DD

Accuracy, Usability, and Adherence of Smartwatches for Atrial Fibrillation Detection in Older Adults After Stroke: Randomized Controlled Trial

JMIR Cardio 2023;7:e45137

DOI: 10.2196/45137

PMID: 38015598

PMCID: 10716742

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.