Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Cardio

Date Submitted: Dec 7, 2021
Open Peer Review Period: Dec 6, 2021 - Jan 31, 2022
Date Accepted: May 17, 2022
(closed for review but you can still tweet)

The final, peer-reviewed published version of this preprint can be found here:

Virtual Reality Cardiac Surgical Planning Software (CorFix) for Designing Patient-Specific Vascular Grafts: Development and Pilot Usability Study

Kim B, Nguyen P, Loke YH, Cleveland V, Liu X, Mass P, Hibino N, Olivieri L, Krieger A

Virtual Reality Cardiac Surgical Planning Software (CorFix) for Designing Patient-Specific Vascular Grafts: Development and Pilot Usability Study

JMIR Cardio 2022;6(1):e35488

DOI: 10.2196/35488

PMID: 35713940

PMCID: 9250062

CorFix: Virtual Reality Cardiac Surgical Planning Software for Designing Patient-Specific Vascular Grafts: Development and Pilot Usability Study

  • Byeol Kim; 
  • Phong Nguyen; 
  • Yue-Hin Loke; 
  • Vincent Cleveland; 
  • Xiaolong Liu; 
  • Paige Mass; 
  • Narutoshi Hibino; 
  • Laura Olivieri; 
  • Axel Krieger

ABSTRACT

Background:

Patients with single ventricle heart defects receives three stages of surgeries culminating in the Fontan surgery. During the Fontan surgery, a vascular graft is sutured between the inferior vena cava and pulmonary artery to divert deoxygenated blood flow to the lungs via passive flow. Customizing the graft configuration can maximize the long-term benefits of Fontan surgery. However, planning patient-specific surgery has several challenges including the ability for physicians to customize grafts and evaluate its hemodynamic performance.

Objective:

The aim of this study was to develop a virtual reality (VR) Fontan graft modeling and evaluation software for physicians. User study was performed to achieve three additional goals: 1) evaluate the software when used by medical doctors and engineers, 2) identify if doctors have a baseline intuition about hemodynamic performance of Fontan grafts in a VR setting, and 3) explore the impact of viewing hemodynamic simulation results in numerical and graphical formats.

Methods:

A total of 5 medical professionals including 4 physicians (1 fourth-year resident, 1 third-year cardiac fellow, 1 pediatric intensivist, and 1 pediatric cardiac surgeon) and 1 biomedical engineer voluntarily participated in the study. The study was pre-scripted to minimize the variability of the interactions between the experimenter and the participants. Unless a participant was familiar with the Fontan surgery, a quick information session was provided at the start. Then, all participants were trained to use the VR gear and our software, CorFix. Each participant designed one bifurcated and one tube-shaped Fontan graft for a single patient. Then a hemodynamic performance evaluation was completed, allowing the participants to further modify their tube-shaped design. The design time and hemodynamic performance for each graft design were recorded. At the end of the study, all participants were provided surveys to evaluate the usability and learnability of the software and rate the intensity of VR sickness.

Results:

The average time for creating one bifurcated and one tube-shaped grafts after a single 10-minute training were 13.40 and 5.49 minutes, accordingly. Three out of 5 bifurcated and 1 out of 5 tube-shaped graft designs were in the benchmark range of hepatic flow distribution. Reviewing hemodynamic performance results and modifying the tube-shaped design took an average time of 2.92 minutes. Participants who modified their tube-shaped graft designs were able to improve the non-physiologic wall shear stress percentage by 7.02%. All tube-shaped graft designs improved wall shear stress compared the native surgical case of the patient. None of the designs met the benchmark indexed power loss.

Conclusions:

VR graft design software can quickly be taught to physicians without any engineering background and VR experience. Improving the system of CorFix could improve performance of the users in customizing and optimizing grafts for patients. With graphical visualization, physicians were able to improve wall shear stress of a tube-shaped graft, lowering the chance of thrombosis. Bifurcated graft designs showed potential strength in better flow split to the lungs, reducing the risk for pulmonary arteriovenous malformations.


 Citation

Please cite as:

Kim B, Nguyen P, Loke YH, Cleveland V, Liu X, Mass P, Hibino N, Olivieri L, Krieger A

Virtual Reality Cardiac Surgical Planning Software (CorFix) for Designing Patient-Specific Vascular Grafts: Development and Pilot Usability Study

JMIR Cardio 2022;6(1):e35488

DOI: 10.2196/35488

PMID: 35713940

PMCID: 9250062

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.