Previously submitted to: Journal of Medical Internet Research (no longer under consideration since Dec 13, 2021)
Date Submitted: Dec 7, 2021
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
A Novel End-to-End Deep Learning Solution for Automatic Coronary Artery Segmentation from CCTA: Algorithm Development and Validation Study
ABSTRACT
Background:
Coronary computed tomographic angiography (CCTA) plays a vital role in the diagnosis of cardiovascular diseases, among which automatic Coronary Artery Segmentation (CAS) serves as one of the most challenging tasks. To computationally assist the task, this paper proposes a novel DL solution.
Objective:
This study introduces an end-to-end novel deep learning-based (DL) solution for automatic CAS.
Methods:
Inspired by the Di-Vnet network, a fully automatic multistage DL solution is proposed. The new solution aims to preserve the integrity of blood vessels in terms of both their shape details and continuity. The solution is developed using 338 CCTA cases, among which 133 cases (33865 axial images) have their groundtruth cardiac masks pre-annotated and 205 cases (53365 axial images) have their groundtruth coronary artery (CA) masks pre-annotated. DSC and 95% HD scores are used to measure the solution’s accuracy in CAS.
Results:
The proposed solution attains (90.29±1.38) % in its DSC and (2.11±0.24) mm in its 95% HD respectively, which consumes 0.112 seconds per image and 30 seconds per case on average.
Conclusions:
The proposed solution attains (90.29±1.38) % in its DSC and (2.11±0.24) mm in its 95% HD respectively, which consumes 0.112 seconds per image and 30 seconds per case on average.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.