Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Previously submitted to: JMIR mHealth and uHealth (no longer under consideration since Jul 06, 2021)

Date Submitted: Apr 2, 2021

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

A Novel Cardiac Force Index Measured by Digital Devices and Applied to the G Tolerance Test among Military Aircrew: An Observational Study

  • Kwo-Tsao Chiang; 
  • Min-Yu Tu; 
  • You-Jin Lin; 
  • Yi-Hsiang Hsin; 
  • Yu-Lung Chiu; 
  • Fang-Ling Li; 
  • Hsin-Hui Chen; 
  • Chung-Yu Lai

ABSTRACT

Background:

Military aircrew are occupationally exposed to a high-G environment. G force causes blood to flow to the lower body region and challenges their cardiac function and anti-G straining maneuver effectiveness. A tolerance test is necessary for every military aircrew member before undergoing flight training. A novel cardiac force index (CFI) has been developed and used to assess long-distance running by mobile health (mHealth) technology. There is still no study to monitor the CFI by wearable devices during the G tolerance test.

Objective:

We added the cardiac function parameter CFI to the G tolerance test and elucidated the relationship between cardiac function and G tolerance among military aircrew.

Methods:

A noninvasive device, BioHarness 3.0, was used to measure heart rate (HR) and activity while resting and walking on the ground. The mathematical formula for cardiac function calculation is CFI = weight × activity/HR. The cardiac force ratio (CFR) is calculated by walking CFI (WCFI)/resting CFI (RCFI). G tolerance includes relaxed G tolerance (RGT) and straining G tolerance (SGT) tested by a human centrifuge under the gradual-onset-rate profile.

Results:

In total, 92 male participants voluntarily completed this study. The average values of RCFI, WCFI, and CFR were 0.02 [SD 0.04], 0.15 [SD 0.04], and 10.77 [SD 4.11], respectively. The mean RGT and SGT were 5.1G [SD 0.9] and 7.8G [SD 1.1], respectively, in the centrifuge. The percentages of participants with RGT greater than 5G or SGT greater than 8G were equally noted as 54.3%. Each 100-unit increase in WCFI increased RGT by 0.14G [SE 0.02, 95% CI 0.09 to 0.19] and by 0.17G [SE 0.03, 95% CI 0.11 to 0.22], corresponding to SGT. In addition, there was an increased chance of RGT values higher than 5G and SGT values higher than 8G according to the increase in WCFI.

Conclusions:

Our results suggested that WCFI is positively correlated with G tolerance in the centrifuge and has the potential to be used for military aircrew selection.


 Citation

Please cite as:

Chiang KT, Tu MY, Lin YJ, Hsin YH, Chiu YL, Li FL, Chen HH, Lai CY

A Novel Cardiac Force Index Measured by Digital Devices and Applied to the G Tolerance Test among Military Aircrew: An Observational Study

JMIR Preprints. 02/04/2021:28853

DOI: 10.2196/preprints.28853

URL: https://preprints.jmir.org/preprint/28853

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.