Recurrence plot and machine learning for signal quality assessment of photoplethysmogram in mobile environment

  • Donggeun Roh; 
  • Hangsik Shin

ABSTRACT

Background:

In clinical use of photoplethysmogram, waveform distortion due to motion noise or low perfusion may lead to inaccurate analysis and diagnostic results. Therefore, it is necessary to find an appropriate analysis method to evaluate the signal quality of the photoplethysmogram so that its wide use in mobile healthcare can be further increased.

Objective:

The purpose of this study was to develop a machine learning model that could accurately evaluate the quality of a photoplethysmogram based on the shape of the photoplethysmogram and the phase relevance in a pulsatile waveform without requiring a complicated pre-processing. Its performance was then verified.

Methods:

Photoplethysmograms were recorded for 76 participants (5 minutes for each participant). All recorded photoplethysmograms were segmented for each beat to obtain a total of 49,561 pulsatile segments. These pulsatile segments were manually labeled as 'good' and 'bad' classes and converted to a two-dimensional phase space trajectory image with size of 124 × 124 using a recurrence plot. The classification model was implemented using a convolutional neural network with a two-layer structure. It was verified through a five-fold cross validation.

Results:

As a result, the proposed model correctly classified 48,827 segments out of 49,561 segments and misclassified 734 segments, showing a balanced accuracy of 0.975. Sensitivity, specificity, and positive predictive values of the developed model for the test dataset with a ‘bad’ class classification were 0.964, 0.987, and 0.848, respectively. The area under the curve was 0.994.

Conclusions:

The convolutional neural network model with recurrence plot as input proposed in this study can be used for signal quality assessment as a generalized model with high accuracy through data expansion. It has an advantage in that it does not require a complicated pre-processing or feature detection process. Clinical Trial: KCT0002080


 Citation

Please cite as:

Roh D, Shin H

Recurrence plot and machine learning for signal quality assessment of photoplethysmogram in mobile environment

JMIR Preprints. 10/12/2020:26410

DOI: 10.2196/preprints.26410

URL: https://preprints.jmir.org/preprint/26410

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.