Accepted for/Published in: JMIR mHealth and uHealth
Date Submitted: Aug 27, 2020
Date Accepted: Apr 8, 2022
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Physical Activity Behavior of Skilled Nursing Facility Patients: A 21-day Longitudinal Cohort Study
ABSTRACT
Background:
The availability of low cost ubiquitous wearable sensors has enabled researchers, in recent years, to collect a large volume of data in various domains including healthcare. The goal has been to harness wearables to further investigate human activity, physiology and functional patterns. As such, on-body sensors have been primarily used in healthcare domain to help predict adverse outcomes such as hospitalizations or fall, thereby enabling clinicians to develop better intervention guidelines and personalized models of care to prevent harmful outcomes. In the previous studies [9,10] and the patent application [11], we introduced a generic framework (Sensing At-Risk Population) that draws on the classification of human movements using a 3-axial accelerometer and extraction of indoor localization using BLE beacons, in concert. This work is to address the longitudinal analyses of a particular cohort using the introduced framework in a skilled nursing facility.
Objective:
(a) To observe longitudinal changes of physical activity and indoor localization features of rehabilitation-dwelling patients, (b) to assess if such changes can be used at early stages during the rehabilitation period to discriminate between patients that will be re-hospitalized versus the ones that will be discharged to a community setting and (c) to investigate if the sensor based longitudinal changes can imitate patients changes captured by therapist assessments over the course of rehabilitation.
Methods:
Pearson correlation was used to compare occupational therapy (OT) and physical therapy (PT) assessments with sensor-based features. Generalized Linear Mixed Model was used to find associations between functional measures with sensor based features.
Results:
Energy intensity at therapy room was positively associated with transfer general (β=0.22;SE=0.08;p<.05). Similarly, sitting energy intensity showed positive association with transfer general (β=0.16;SE=0.07;p<.05). Laying down energy intensity was negatively associated with hygiene grooming (β=-0.27;SE=0.14;p<.05). The interaction of sitting energy intensity with time (β=-0.13;SE=.06;p<.05) was associated with toileting general. Dressing lower body was strongly correlated with overall energy intensity (r = 0.66), standing energy intensity (r = 0.61), and laying down energy intensity (r = 0.72) on the first clinical assessment session.
Conclusions:
This study demonstrates that a combination of indoor localization and physical activity tracking produces a series of features, a subset of which can provide crucial information on the storyline of daily and longitudinal activity patterns of rehabilitation-dwelling patients.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.