Effectiveness Evaluation of Multi-b Value Diffusion Weighted Imaging Intelligence Monitoring the Diagnosis of Benign and Malignant Prostatic Tumors Based on Single-index Model, Double-index Model and Stretch-index Model

  • Ting Zheng; 
  • Jiangtao Wang; 
  • Qian Liu; 
  • Jingzhong Wang; 
  • Jingzhong Wang; 
  • Yongjuan Wu; 
  • John Norris

ABSTRACT

In order to study the effectiveness of multi-b-value diffusion weighted imaging intelligence monitoring in the diagnosis of benign and malignant prostatic tumors under single-index model, double-index model and stretch-index model, the patients with prostatic tumors are selected as the research objects, and the image data and interest area data are processed and analyzed through magnetic resonance diffusion weighted imaging and pathological examination of prostate biopsy. The range is divided into three groups: A, B and C. The goodness of fit of each model is compared, and the diagnostic efficacy of ADC (apparent diffusion coefficient), f (perfusion fraction), D (slow diffusion coefficient), D* (rapid diffusion coefficient), DDC (distribution diffusion coefficient) and ɑ (diffusion heterogeneity index) in differentiating benign and malignant prostate tumors is evaluated. The results show that the goodness of fit of single exponential model is low. Adjusted R2 (correction determinant coefficient) decreases with the increase of the maximum b value of fit. The goodness of fit of double exponential model and tensile exponential model is higher. The parameters of ADC, D, DDC and ɑ value of cancer tissue and f value of group A are lower than those of benign tissue. There is no significant difference in parameters D* and f values between benign and cancerous tissues in group B and C, suggesting that the parameters ADC, D, DDC and ɑ value can be used as the basis for differentiating benign and malignant diseases of prostate, while the values of D* and f have no diagnostic efficacy. In the single index model, the ADC value is the most effective parameter to differentiate benign and malignant prostatic tumors on the premise that the b value is 0-2000 s/mm2 and less than 2000 s/mm2. The values of D, DDC and ɑ in the double exponential model and the stretch exponential model can provide more diagnostic information and have higher diagnostic value, but their sensitivity and specificity have little advantage, so these parameters can be used as supplements to the single exponential model.


 Citation

Please cite as:

Zheng T, Wang J, Liu Q, Wang J, Wang J, Wu Y, Norris J

Effectiveness Evaluation of Multi-b Value Diffusion Weighted Imaging Intelligence Monitoring the Diagnosis of Benign and Malignant Prostatic Tumors Based on Single-index Model, Double-index Model and Stretch-index Model

JMIR Preprints. 01/04/2020:19050

DOI: 10.2196/preprints.19050

URL: https://preprints.jmir.org/preprint/19050

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.