ABSTRACT
Background:
Guidelines provide instructions for diagnostics and therapy in modern medicine. Various mobile devices are used to represent the potential complex decision trees. An example of time-critical decisions is triage in case of a mass casualty incident.
Objective:
In this randomized controlled cross-over study, the potential of augmented reality for guideline presentation was evaluated and compared with a tablet PC as a conventional device.
Methods:
A specific Android app was designed for use with Smart Glasses as well as with a tablet PC for presentation of a triage algorithm as an example for a complex guideline. 40 volunteers simulated a triage based on 30 fictional patient descriptions each, with technical support from data glasses and a tablet PC in cross-over trial design. The time to come to a decision and the accuracy were recorded and compared between the different devices.
Results:
A total of 2400 assessments were performed. A significantly faster triage time has been achieved with the tablet PC (12.8 sec) compared to the smart glasses (17.5 sec; P = .001) in total. Considering the difference in triage duration between both devices, the additional time needed with the smart glasses could be reduced significantly in the course (P = .001). In accuracy of guideline decisions, there was no significant difference comparing both devices.
Conclusions:
The presentation of a guideline on a tablet computer, as well as in the form of augmented reality, achieved good results. The implementation using smart glasses took more time due to a more complex operating concept but could be accelerated in the course of the study after adaptation. Especially in a non-time-critical working area where hands-free interfaces are meaningful, a guideline presentation with augmented reality can already be implemented.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.