Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
The Effect of a Cellular-Enabled Glucose Meter on Glucose Control for Patients With Diabetes: Prospective Pre-Post Study
Background:
Diabetes is a global epidemic affecting approximately 30 million people in the United States. The World Health Organization recommends using technology and telecommunications to improve health care delivery and disease management. The Livongo for Diabetes Program offers a remote monitoring technology with Certified Diabetes Educator outreach.
Objective:
The purpose of this study was to examine health outcomes measured by changes in HbA1c, in time in target blood glucose range, and in depression symptoms for patients enrolled in a remote digital diabetes management program in a Diabetes Center of Excellence setting.
Methods:
The impact of the Livongo for Diabetes program on hemoglobin A1c (HbA1c), blood glucose ranges, and depression screening survey results (Patient Health Questionnaire-2 [PHQ-2]) were assessed over 12 months in a prospective cohort recruited from the University of South Florida Health Diabetes Home for Healthy Living. Any patient ≥18 years old with a diagnosis of diabetes was approached for voluntary inclusion into the program. The analysis was a pre-post design for those members enrolled in the study. Data was collected at outpatient clinic visits and remotely through the Livongo glucose meter.
Results:
A total of 86 adults were enrolled into the Livongo for Diabetes program, with 49% (42/86) female, an average age of 50 (SD 15) years, 56% (48/86) with type 2 diabetes mellitus, and 69% (59/86) with insulin use. The mean HbA1c drop amongst the group was 0.66% (P=.17), with all participants showing a decline in HbA1c at 12 months. A 17% decrease of blood glucose checks <70 mg/dL occurred concurrently. Participants with type 2 diabetes not using insulin had blood glucose values within target range (70-180 mg/dL) 89% of the time. Participants with type 2 diabetes using insulin were in target range 68% of the time, and type 1 diabetes 58% of the time. Average PHQ-2 scores decreased by 0.56 points during the study period.
Conclusions:
Participants provided with a cellular-enabled blood glucose meter with real-time feedback and access to coaching from a certified diabetes educator in an outpatient clinical setting experienced improved mean glucose values and fewer episodes of hypoglycemia relative to the start of the program.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.