Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR mHealth and uHealth

Date Submitted: Feb 21, 2019
Open Peer Review Period: Feb 25, 2019 - Apr 11, 2019
Date Accepted: Aug 31, 2019
(closed for review but you can still tweet)

The final, peer-reviewed published version of this preprint can be found here:

The Mobile-Based 6-Minute Walk Test: Usability Study and Algorithm Development and Validation

Salvi D, Poffley E, Orchard E, Tarassenko L

The Mobile-Based 6-Minute Walk Test: Usability Study and Algorithm Development and Validation

JMIR Mhealth Uhealth 2020;8(1):e13756

DOI: 10.2196/13756

PMID: 31899457

PMCID: 6969385

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

The Mobile-Based 6-Minute Walk Test: Usability Study and Algorithm Development and Validation

  • Dario Salvi; 
  • Emma Poffley; 
  • Elizabeth Orchard; 
  • Lionel Tarassenko

Background:

The 6-min walk test (6MWT) is a convenient method for assessing functional capacity in patients with cardiopulmonary conditions. It is usually performed in the context of a hospital clinic and thus requires the involvement of hospital staff and facilities, with their associated costs.

Objective:

This study aimed to develop a mobile phone–based system that allows patients to perform the 6MWT in the community.

Methods:

We developed 2 algorithms to compute the distance walked during a 6MWT using sensors embedded in a mobile phone. One algorithm makes use of the global positioning system to track the location of the phone when outdoors and hence computes the distance travelled. The other algorithm is meant to be used indoors and exploits the inertial sensors built into the phone to detect U-turns when patients walk back and forth along a corridor of fixed length. We included these algorithms in a mobile phone app, integrated with wireless pulse oximeters and a back-end server. We performed Bland-Altman analysis of the difference between the distances estimated by the phone and by a reference trundle wheel on 49 indoor tests and 30 outdoor tests, with 11 different mobile phones (both Apple iOS and Google Android operating systems). We also assessed usability aspects related to the app in a discussion group with patients and clinicians using a technology acceptance model to guide discussion.

Results:

The mean difference between the mobile phone-estimated distances and the reference values was −2.013 m (SD 7.84 m) for the indoor algorithm and −0.80 m (SD 18.56 m) for the outdoor algorithm. The absolute maximum difference was, in both cases, below the clinically significant threshold. A total of 2 pulmonary hypertension patients, 1 cardiologist, 2 physiologists, and 1 nurse took part in the discussion group, where issues arising from the use of the 6MWT in hospital were identified. The app was demonstrated to be usable, and the 2 patients were keen to use it in the long term.

Conclusions:

The system described in this paper allows patients to perform the 6MWT at a place of their convenience. In addition, the use of pulse oximetry allows more information to be generated about the patient’s health status and, possibly, be more relevant to the real-life impact of their condition. Preliminary assessment has shown that the developed 6MWT app is highly accurate and well accepted by its users. Further tests are needed to assess its clinical value.


 Citation

Please cite as:

Salvi D, Poffley E, Orchard E, Tarassenko L

The Mobile-Based 6-Minute Walk Test: Usability Study and Algorithm Development and Validation

JMIR Mhealth Uhealth 2020;8(1):e13756

DOI: 10.2196/13756

PMID: 31899457

PMCID: 6969385

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.