Accepted for/Published in: JMIR mHealth and uHealth
Date Submitted: Feb 18, 2019
Open Peer Review Period: Feb 21, 2019 - Apr 18, 2019
Date Accepted: Feb 22, 2020
(closed for review but you can still tweet)
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Derivation of Breathing Metrics From a Photoplethysmogram at Rest: Machine Learning Methodology
Background:
There has been a recent increased interest in monitoring health using wearable sensor technologies; however, few have focused on breathing. The ability to monitor breathing metrics may have indications both for general health as well as respiratory conditions such as asthma, where long-term monitoring of lung function has shown promising utility.
Objective:
In this paper, we explore a long short-term memory (LSTM) architecture and predict measures of interbreath intervals, respiratory rate, and the inspiration-expiration ratio from a photoplethysmogram signal. This serves as a proof-of-concept study of the applicability of a machine learning architecture to the derivation of respiratory metrics.
Methods:
A pulse oximeter was mounted to the left index finger of 9 healthy subjects who breathed at controlled respiratory rates. A respiratory band was used to collect a reference signal as a comparison.
Results:
Over a 40-second window, the LSTM model predicted a respiratory waveform through which breathing metrics could be derived with a bias value and 95% CI. Metrics included inspiration time (–0.16 seconds, –1.64 to 1.31 seconds), expiration time (0.09 seconds, –1.35 to 1.53 seconds), respiratory rate (0.12 breaths per minute, –2.13 to 2.37 breaths per minute), interbreath intervals (–0.07 seconds, –1.75 to 1.61 seconds), and the inspiration-expiration ratio (0.09, –0.66 to 0.84).
Conclusions:
A trained LSTM model shows acceptable accuracy for deriving breathing metrics and could be useful for long-term breathing monitoring in health. Its utility in respiratory disease (eg, asthma) warrants further investigation.
Citation
Per the author's request the PDF is not available.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.