Accepted for/Published in: JMIR mHealth and uHealth
Date Submitted: Dec 15, 2018
Open Peer Review Period: Dec 18, 2018 - Feb 12, 2019
Date Accepted: Mar 24, 2019
Date Submitted to PubMed: Mar 25, 2019
(closed for review but you can still tweet)
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
The Use of Wireless, Smartphone App–Assisted Home Blood Pressure Monitoring Among Hypertensive Patients in Singapore: Pilot Randomized Controlled Trial
Background:
Reliable home blood pressure monitoring (HBPM) is essential to effective hypertension management; however, manual recording is subject to underreporting and inaccuracies. Mobile health technologies hold great potential as HBPM tools, but the fidelity of a smartphone app in HBPM has not been adequately assessed.
Objective:
The primary aim of the trial was to compare the fidelity of a smartphone app to that of a handwritten logbook in making HBPM data available to clinicians at follow-up visits. Fidelity was defined as the percentage of scheduled blood pressure (BP) recordings over a 3-week period that were properly recorded and reported to the clinic. The secondary aims were to investigate patient factors associated with HBPM fidelity and to explore the effect of time on the fidelity.
Methods:
A 2-arm, parallel, unblinded, randomized controlled pilot trial was conducted in a government polyclinic in Singapore. Hypertensive adults, aged 40 to 70 years, who were on antihypertensive medication and owned a smartphone were recruited and randomized by a computer-generated randomization schedule to 3 weeks of either semiautomated HBPM utilizing a Bluetooth-enabled BP monitor and a smartphone app or a fully manual process utilizing a conventional handwritten logbook. The primary outcome was home BP recording fidelity.
Results:
Of the 80 patients randomized, 79 (smartphone app: 38 and logbook: 41) were included in the final analysis. Although fidelity was higher among the app users, it did not differ significantly between study arms (smartphone app: 66.7% and logbook: 52.4%; P=.21). Chinese and Indian ethnicities were associated with higher fidelity (absolute percent and 95% CI) by 35.6% (4.27 to 66.9) and 45.0% (8.69 to 81.3), respectively, in comparison with other ethnicities (P=.03); longer smartphone ownership increased fidelity on an average of 10.5% (0.83 to 20.2) per year (P=.03); the number of apps on the smartphone decreased fidelity at a rate of −0.32% (−0.58 to −0.05) per app (P=.02); years of hypertension morbidity increased fidelity at a rate of 1.56% (0.03 to 3.09) per year (P=.046); and the number of people working in the household decreased fidelity at a rate of −8.18% (−16.3 to −0.08) per additional working person (P=.048). The fidelity of the app was significantly higher in the first week (64.4%) than the second (55.1%, P=.001) and third (58.2%, P=.03) weeks of monitoring.
Conclusions:
Amid the increasing integration of health technologies into clinical practice, our study demonstrates the feasibility of smartphone app–assisted HBPM in hypertensive adults of Singapore. Our pilot study found no statistically significant difference in mean BP recording fidelity between a smartphone app and conventional handwritten logbook. However, the small sample size precludes definitive conclusions and highlights the need for a larger, adequately powered trial.
ClinicalTrial:
ClinicalTrials.gov NCT03209024; https://clinicaltrials.gov/ct2/show/NCT03209024 (Archived by WebCite at http://www.webcitation.org/78EVWBg0T)
Citation
Per the author's request the PDF is not available.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.