Smartphone-Measured Turning Performance During Routine Timed Up and Go Tests and 30-Day Fall Risk in Skilled Nursing Facility Residents: Retrospective Cohort Study
ABSTRACT
Background:
Falls in skilled nursing facilities (SNFs) are common and serious, yet most residents meet broad "high-risk" criteria, limiting the value of screening for prioritizing care. The Timed Up and Go (TUG) test is widely used, but its total duration discriminates poorly between fallers and non-fallers in frail populations. Turning is a demanding part of the TUG and everyday mobility that smartphone sensors can quantify during routine testing. Small studies using research-grade sensors found that peak angular velocity (PAV) during a 180° turn distinguished fallers from non-fallers. However, these studies were conducted outside routine care, and none tested whether PAV predicts near-term falls more accurately than total TUG duration.
Objective:
To examine whether smartphone-measured PAV during the 180° turn of a routine TUG better identifies SNF residents who fall within 30 days than total TUG duration does.
Methods:
This retrospective cohort study included US SNF residents whose electronic health records (EHRs) were integrated with a smartphone mobility-assessment app. From January through October 2026, residents entered at their first smartphone TUG with a detected 180° turn after structured fall reporting began. The outcome was the first EHR-recorded fall within 30 days of cohort entry, with follow-up censored at discharge or death. We assessed discrimination using the Harrell C-index (primary) and the area under the receiver operating characteristic curve (AUC), with paired bootstrap comparisons. We evaluated a median PAV threshold selected without reference to outcomes using Kaplan-Meier, Cox, and competing-risk methods. We assessed convergent validity against turn PAV from same-day smartphone walks.
Results:
Of 351 residents (mean age 79.6, SD 10.5 years; 61.7% women), 44 (12.5%) fell within 30 days. Fallers had lower PAV (median 35.0 vs 41.2 °/s; P=.02). TUG duration did not differ (P=.46). PAV discriminated better than TUG duration (C-index 0.609 vs 0.534; difference 0.076, 95% CI 0.012-0.145; P=.02; AUC 0.631 vs 0.513; P=.003). Below the median PAV of 40.4 °/s, estimated 30-day fall risk was about twice as high (22.5% vs 10.9%; hazard ratio [HR] 2.26, 95% CI 1.20-4.27; negative predictive value 84%). Splitting TUG duration at its median did not distinguish risk (HR 0.76). Findings were consistent after adjustment for age and sex and stratification by organization (HR 2.52), with TUG duration in the same model (HR 2.95), and when discharge was treated as a competing event. PAV discrimination was stable from 1 to 4 weeks. TUG-turn and same-day walking-turn PAV were moderately correlated (Spearman ρ=0.61; intraclass correlation coefficient [ICC] 0.71; n=54).
Conclusions:
In this exploratory SNF cohort, smartphone-measured turn PAV showed modest discrimination of 30-day fall risk and outperformed total TUG duration. A threshold of about 40 °/s identified residents with twice the observed 30-day risk. Validation in larger, multisite cohorts is warranted before clinical adoption.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.