Real-Time Wearable IMU-Based Audio Biofeedback for Improving Knee Movement Accuracy in Healthy Adults: A Randomized Crossover Study
ABSTRACT
Background:
Therapeutic exercise is a fundamental component of rehabilitation following musculoskeletal injury and surgery. Although supervised rehabilitation provides continuous guidance and corrective feedback, exercise performance in home-based settings is largely unsupervised.
Objective:
Wearable technologies with real-time feedback may provide an accessible means of improving movement accuracy during therapeutic exercise. This study aimed to evaluate the effect of a wearable inertial measurement unit (IMU)-based audio biofeedback system on knee movement accuracy during three commonly performed exercises.
Methods:
Twenty healthy adults were recruited, of whom 15 completed the study. Participants performed seated leg extensions, sit-to-stands, and squats in a randomized crossover design, completing each exercise with and without real-time audio biofeedback. The system incorporated two IMU sensors positioned on the thigh and calf to estimate knee joint orientation and deliver real-time auditory cues when predefined movement targets were reached. Movement accuracy was quantified using mean absolute error (MAE) in knee joint orientation across repetitions. Data distribution was assessed using the Shapiro–Wilk test. Paired t-tests with Cohen’s d were used for normally distributed outcomes, whereas Wilcoxon signed-rank tests with rank-based effect sizes (r) were used for non-normally distributed outcomes. In addition, repetition-wise mean knee joint trajectories across 30 repetitions were modeled using multilayer perceptron neural networks and ensemble averaging to characterize performance trends and extrapolate trajectories to 80 repetitions.
Results:
Squat performance showed a significant improvement with audio biofeedback compared with the no-feedback condition (p < 0.001, Cohen’s d = −1.43), indicating a large effect. No significant differences were observed for sit-to-stand (p = 0.29, r = −0.27) or seated leg extension (p = 0.64, r = −0.12).
Conclusions:
Real-time wearable audio biofeedback improved knee movement accuracy during squats but did not provide significant additional benefits during seated leg extensions or sit-to-stands. These findings suggest that the potential benefit of real-time auditory feedback may be greater during more complex, multi-joint exercises. Further studies in clinical populations are warranted to determine whether this approach can support rehabilitation delivered in home-based settings.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.