Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Currently submitted to: JMIR Biomedical Engineering

Date Submitted: Nov 10, 2026
Open Peer Review Period: Nov 20, 2026 - Jan 15, 2027
(currently open for review)

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Sensor-Informed Nicotine Tapering: A Constrained, Occupancy-Informed Step-Down Target Curve for Digital Reduction Systems

  • Brain John Aboze; 
  • Adewale Owobowale

ABSTRACT

This viewpoint argues that digital nicotine step-down systems should follow a constrained, occupancy-informed target curve and should be steered by sensor data rather than labeled strength alone. Reducing smoking gradually before quitting is as effective as stopping abruptly for long-term abstinence, and e-cigarettes with stepped liquid strengths and device telemetry can now deliver and measure a reduction schedule, yet nicotine reduction tools rarely specify how much to cut at each step. We draw on deprescribing guidance for opioids, benzodiazepines, and antidepressants, where six tapering principles recur and faster opioid tapers are associated with measurably higher harm. We then anchor a step-down curve to the measured α4β2* nicotinic receptor occupancy curve (half-occupancy at 0.87 ng/mL venous plasma nicotine). In an illustrative model, linear concentration cuts back-load occupancy change onto the final steps; over 10 steps to a 5% occupancy floor, equal-occupancy steps from 20 ng/mL demand a 71.5% first cut; and a 25% per-step constraint needs at least 22 steps to reach that floor. Because users partly compensate by puffing harder, the curve needs dual-axis input: delivered concentration and puff topography. Three messages follow. First, digital tapering systems should state a quantitative reduction schedule with explicit per-step constraints, pause rules, and patient override. Second, concentration-only schedules are insufficient; sensor-measured topography must feed the next step. Third, whether equalizing occupancy steps equalizes withdrawal is untested and must be decided by prospective trials.


 Citation

Please cite as:

Aboze BJ, Owobowale A

Sensor-Informed Nicotine Tapering: A Constrained, Occupancy-Informed Step-Down Target Curve for Digital Reduction Systems

JMIR Preprints. 10/11/2026:116639

DOI: 10.2196/preprints.116639

URL: https://preprints.jmir.org/preprint/116639

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.