Real-Time Artificial Intelligence Assistance for Peripheral Nerve Ultrasound Training in Radiology Residents: A Randomized Crossover Study

  • Sylvain Grange; 
  • Daniel J Chin; 
  • Teo Lopez-Bernal; 
  • Karthik Shyam; 
  • Mathieu Boily; 
  • Karl Muchantef; 
  • Natalia Gorelik; 
  • Jean-Pierre Pelage

ABSTRACT

Background:

Peripheral nerve ultrasound is technically demanding for novice operators and requires precise anatomical knowledge and image interpretation skills. Real-time artificial intelligence (AI) assistance may facilitate nerve recognition and support ultrasound training. However, its impact on trainee performance and perceived educational value remains insufficiently investigated.

Objective:

To evaluate whether real-time AI assistance improves peripheral nerve identification performance among radiology residents and to assess its potential educational benefits and limitations.

Methods:

This prospective randomized crossover study included 15 radiology residents with no previous experience in peripheral nerve ultrasound. Participants performed bilateral identification of the median, ulnar, and radial nerves, with and without real-time AI assistance using NerveTrack (Samsung). Each resident completed 12 randomized identification attempts, yielding 90 matched comparisons. The primary outcome was successful nerve identification within 60 seconds, assessed by senior musculoskeletal radiologists. Secondary outcomes included identification time, confidence, perceived difficulty, AI overlay accuracy, anatomical scanning location, and resident and faculty perceptions.

Results:

Fifteen residents completed 180 identification attempts. Successful nerve identification increased from 52.2% (47/90) without AI to 65.6% (59/90) with AI assistance (exact McNemar P=.036), although the resident-level sensitivity analysis was not statistically significant (P=.125). Mean identification time decreased from 34.1 (SD 9.7) to 25.3 (SD 8.1) seconds (P=.001). Confidence increased from 4.6 (SD 1.8) to 6.4 (SD 1.1) on a 0–10 scale (P<.001), while perceived difficulty decreased from 5.8 (SD 1.7) to 4.6 (SD 1.7) (P=.001). Appropriate anatomical scanning location remained unchanged (74.4% in both conditions). The largest numerical improvement in identification success was observed among first-year residents, although differences across training levels were not statistically significant. AI overlay accuracy varied according to anatomical target, highlighting the importance of expert supervision.

Conclusions:

Real-time AI assistance was associated with faster peripheral nerve identification, increased confidence, and reduced perceived difficulty among radiology residents. Although identification success improved at the matched-attempt level, this finding was not statistically significant in the resident-level sensitivity analysis. These results suggest that AI-assisted ultrasound may support supervised training, but further studies are needed to determine whether these immediate performance benefits translate into sustained, independent ultrasound skills. Clinical Trial: No


 Citation

Please cite as:

Grange S, Chin DJ, Lopez-Bernal T, Shyam K, Boily M, Muchantef K, Gorelik N, Pelage JP

Real-Time Artificial Intelligence Assistance for Peripheral Nerve Ultrasound Training in Radiology Residents: A Randomized Crossover Study

JMIR Preprints. 08/11/2026:116465

DOI: 10.2196/preprints.116465

URL: https://preprints.jmir.org/preprint/116465

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.