Currently submitted to: JMIR Medical Informatics
Date Submitted: Sep 29, 2026
Open Peer Review Period: Oct 8, 2026 - Dec 3, 2026
(currently open for review)
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Semantic feature decoupling and contrastive boundary-guided attention for colorectal polyp segmentation: a comparative evaluation of decoder designs
ABSTRACT
Background:
Comparisons of decoder modules for automated polyp segmentation are complicated by differences in encoder backbones, training protocols, and data splits. This study evaluates decoder modules under matched conditions and investigates a decoder combining semantic feature decoupling with boundary-guided attention.
Objective:
To evaluate decoder modules for colorectal polyp segmentation under matched conditions and develop a semantic decoupling and boundary-guided attention framework.
Methods:
Ten decoder modules were compared with a plain convolutional baseline using a fixed Twins-PCPVT-Small encoder and matched training settings. We developed ConBPoly, combining a Semantic Information Decoupling Module with Contrastive Boundary-Guided Attention, and evaluated architectural components and auxiliary loss configurations. Training used 1,450 images from Kvasir-SEG and CVC-ClinicDB; evaluation used 738 images across four test sets. Analyses included per-image paired Wilcoxon tests, bootstrap confidence intervals, and three-seed validation of the proposed configurations.
Results:
Three of ten modules exceeded the heuristic Kvasir-SEG screening threshold of Dice > 0.9142. ConBPoly-min achieved a Kvasir-SEG Dice of 0.9246 in the primary run and 0.9203 ± 0.0032 across three controlled training seeds. Its primary-run Kvasir-SEG Dice exceeded those of SSFormer (0.9197) and Polyp-PVT (0.9190). However, Polyp-PVT achieved a higher four-dataset mean Dice (0.8596 versus 0.8490). Removing auxiliary objectives from the original ConBPoly loss configuration increased Kvasir-SEG Dice by 0.0065, while the benefits of loss simplification varied across datasets.
Conclusions:
Under the evaluated backbone and training protocol, decoder module benefits were dataset-dependent. ConBPoly combined competitive Kvasir-SEG segmentation with a simplified training objective, but its cross-domain performance remained below Polyp-PVT. These findings support controlled evaluation of decoder design and further investigation of semantic decoupling and boundary-guided refinement. Validation across additional encoders and clinical video data is needed.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.