Warning: This is a unreviewed preprint (What is a preprint?). Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn (a note "no longer under consideration" will appear above).
Peer review me: Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period (in this case, a "Peer Review Me" button to sign up as reviewer is displayed above). All preprints currently open for review are listed here. Outside of the formal open peer-review period we encourage you to tweet about the preprint.
Citation: Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author).
Final version: If our system detects a final peer-reviewed "version of record" (VoR) published in any journal, a link to that VoR will appear below. Readers are then encourage to cite the VoR instead of this preprint.
Settings: If you are the author, you can login and change the preprint display settings, but the preprint URL/DOI is supposed to be stable and citable, so it should not be removed once posted.
Submit: To post your own preprint, simply submit to any JMIR journal, and choose the appropriate settings to expose your submitted version as preprint.
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Integrated Right Atrial Strain and Cardiorenal Risk Stratification in Heart Failure With Preserved Ejection Fraction Using a 3-Agent Artificial Intelligence Pipeline: Development and Preliminary Evaluation Study
ABSTRACT
Background:
Risk stratification in heart failure with preserved ejection fraction (HFpEF) is impeded by multidimensional cardiorenal dysfunction, spanning metabolic derangement, right atrial (RA) strain impairment, and renal deterioration. Translating prognostic models into point-of-care decisions remains a critical unmet need.
Objective:
We developed and preliminarily evaluated CARE-Agent (Cardiorenal Autonomous Risk Evaluation Agent), a 3-agent artificial intelligence (AI) pipeline integrating right atrial strain classification, a Cox risk-ranking component, and large language model (LLM)–generated structured explanations for HFpEF risk stratification. We also conducted an exploratory comparison of candidate LLMs for the optional reasoning layer.
Methods:
This development and preliminary evaluation study used a secondary analysis of a previously reported single-center cohort of 395 patients with HFpEF (Gansu Provincial Hospital, October 2023-October 2024; median follow-up 18.9 months; composite end point: cardiovascular death or HF rehospitalization). Agent A retrieved and checked structured data and applied prespecified risk flags; Agent B classified 3 phases of right atrial strain; and Agent C combined a cohort-derived 11-variable Cox risk ranking, right atrial classification, and 8 advisory rules into 4 descriptive tiers. The optional LLM layer generated a structured explanation and a separate safety-check output. Six LLM configurations were compared in 20 stratified cases (120 generations), with outputs rated by 3 clinician coauthors blinded to model identity.
Results:
Overall, 158 of 395 patients (40.0%) reached the composite end point. Apparent within-cohort event proportions increased across the integrated tiers from 0% (LOW) and 2.4% (MODERATE) to 32.6% (HIGH) and 78.5% (CRITICAL; P<.001 for trend); these values are resubstitution results from the development cohort and are not estimates of external performance. Right atrial function was classified as impaired in 238 patients (60.3%). Across the 6 LLM configurations, structured output was returned in 120 of 120 generations, while mean latency ranged from 8.9 to 312.9 seconds and mean token use from approximately 1380 to 9850. Mean clinician-rated composite scores ranged from 4.05 to 6.69, but interrater reliability was modest (ICC[2,k] −0.05 to 0.37). One configuration returned empty safety-check content in all 20 cases. Because no reference standard for safety flags was used, these findings assess output completeness and rated quality, not clinical safety.
Conclusions:
CARE-Agent demonstrates the technical feasibility of combining deterministic risk components with an optional, structured LLM explanation layer. The current results are preliminary and hypothesis generating; optimism-corrected internal validation, external validation, usability testing, and prospective workflow evaluation are required before clinical use. Clinical Trial: Not applicable; this study was a retrospective secondary analysis and was not a clinical trial.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.