Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR mHealth and uHealth

Date Submitted: Apr 12, 2018
Open Peer Review Period: Apr 13, 2018 - Aug 17, 2018
Date Accepted: Dec 12, 2018
(closed for review but you can still tweet)

The final, peer-reviewed published version of this preprint can be found here:

Change in Waist Circumference With Continuous Use of a Smart Belt: An Observational Study

Lee M, Shin J

Change in Waist Circumference With Continuous Use of a Smart Belt: An Observational Study

JMIR Mhealth Uhealth 2019;7(5):e10737

DOI: 10.2196/10737

PMID: 31045500

PMCID: 6521184

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Change in Waist Circumference With Continuous Use of a Smart Belt: An Observational Study

  • Myeonggyun Lee; 
  • Jaeyong Shin

Background:

Health insurers and policymakers are trying to prevent and reduce cardiovascular diseases due to obesity. A smart belt that monitors activity and waist circumference is a new concept for conquering obesity and may be a promising new strategy for health insurers and policymakers.

Objective:

This preliminary study evaluated whether the use of a smart belt was associated with a decrease in waist circumference.

Methods:

In the manufacturer’s database, there were data on a total of 427 men at baseline. A total of 223, 81, and 27 users kept using the smart belt for 4, 8, and 12 weeks, respectively. Paired t tests and repeated measures analysis of variance (ANOVA) were used to identify the change in waist circumference at specified time intervals (at 4, 8, and 12 weeks). In addition, a linear mixed model was used to incorporate all users’ waist circumference data at each time point. Preexisting data on waist circumference and self-reported demographics were obtained from the manufacturer of the smart belt (WELT Corporation, South Korea).

Results:

Compared with baseline, the waist circumference (cm) decreased significantly at all time points: –0.270 for week 4, –0.761 for week 8, and –1.972 for week 12 (all P<.01). Although each paired t test had a different sample size because of loss to follow-up, the differences between baseline and each subsequent week increased. Equal continuous reduction in waist circumference was observed with the ANOVA and mixed model analysis (beta=–0.158 every week).

Conclusions:

The smart belt is a newly developed, wearable device that measures real-time steps, sedentary time, and waist circumference. In this study, we showed that wearing the smart belt was associated with reducing waist circumference over 12 weeks. This direct-to-consumer smart health device may contribute toward reducing the risk of obesity and related conditions and controlling increasing health costs for health insurers.


 Citation

Please cite as:

Lee M, Shin J

Change in Waist Circumference With Continuous Use of a Smart Belt: An Observational Study

JMIR Mhealth Uhealth 2019;7(5):e10737

DOI: 10.2196/10737

PMID: 31045500

PMCID: 6521184

Per the author's request the PDF is not available.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.