Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Currently accepted at: JMIR Medical Informatics

Date Submitted: Jul 14, 2026
Date Accepted: Nov 5, 2026

This paper has been accepted and is currently in production.

It will appear shortly on 10.2196/106992

The final accepted version (not copyedited yet) is in this tab.

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Reconstruction Fidelity Alone Does Not Predict Downstream Utility in Synthetic Clinical Data: A Tail-Aware Evaluation Protocol for Heavy-Tailed Biomarkers

  • Jung Hun Lee; 
  • Kyu Hee Lee

ABSTRACT

Background:

Clinical data are hard to share, and synthetic clinical data are increasingly used to circulate and reuse information across systems without exposing real records. For such reuse to be safe, downstream utility must be verified before release. Quality is still judged mainly by aggregate distributional similarity, which averages over the distribution tails, where the highest-risk 3–5% of cardiovascular patients and the high-kurtosis biomarkers that flag them lie.

Objective:

We developed and evaluated a reusable tail-aware pre-release evaluation protocol to quantify whether differences in tail-region reconstruction fidelity propagate into downstream classifier utility.

Methods:

Four established scalers (Standard, Robust, Power, Quantile) and a hybrid head-tail scaler were paired with a tabular denoising diffusion probabilistic model (TabDDPM) and a conditional variational autoencoder (CVAE) on the KoGES-ARIRANG cohort (n = 4,928; seven shared high-kurtosis biomarkers). NHANES 2017–2018 provided external validation on the shared variables (n = 1,663). A NHANES-internal analysis widened coverage to 18 high-kurtosis variables by adding 11 NHANES-specific biomarkers. Downstream utility was evaluated using train-on-synthetic, test-on-real analysis across AUROC, AUPRC, recall, and expected calibration error.

Results:

With TabDDPM, scaler choice governed tail-reproduction accuracy from 8.2% to 135.1% of the original, while test-on-real AUROC differed by at most 2.98 points and every scaler pair remained equivalent within a ±0.05 AUROC margin. The pattern held in external validation and across all four metrics. The separation narrowed for the autoencoder, where higher-fidelity scalers improved stroke prediction. The one exception was mode collapse, where near-zero fidelity met chance-level AUROC (0.506–0.511), a boundary that shifted between cohorts. Overall-cohort summaries obscured cross-scaler calibration differences that became more apparent in the tail-enriched high-risk subgroup.

Conclusions:

Reconstruction fidelity alone does not predict downstream utility in synthetic clinical data with heavy-tailed biomarkers. Before such data are shared or reused, tail-region utility should be verified alongside aggregate fidelity using multiple evaluation metrics. Clinical Trial: Not applicable.


 Citation

Please cite as:

Lee JH, Lee KH

Reconstruction Fidelity Alone Does Not Predict Downstream Utility in Synthetic Clinical Data: A Tail-Aware Evaluation Protocol for Heavy-Tailed Biomarkers

JMIR Preprints. 14/07/2026:106992

DOI: 10.2196/preprints.106992

URL: https://preprints.jmir.org/preprint/106992

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.