Accepted for/Published in: JMIR Formative Research
Date Submitted: Jun 26, 2026
Date Accepted: Nov 2, 2026
Absolute agreement between the Garmin Forerunner 55 and research grade accelerometry in free-living conditions: comparison study
ABSTRACT
Background:
Research-grade accelerometers are widely used to monitor physical activity in research, but are often expensive, have limited battery and storage, and impose a high participant burden. Consumer wearables are designed for long-term monitoring and are being extensively used in research. However, evidence regarding their accuracy remains inconsistent.
Objective:
To examine agreement between the Garmin Forerunner 55 and the ActiGraph wGT3X for steps, moderate-to-vigorous physical activity (MVPA), and activity energy expenditure (AEE) in older adults under free-living conditions.
Methods:
We included baseline data from 82 community-dwelling older adults (60-75 years) in the RESTART trial who wore the ActiGraph wGT3X and the Garmin Forerunner 55 simultaneously for 7 days. Valid days were defined as ≥10 hours of wear time per day. We compared mean steps, MVPA and AEE between devices. Agreement was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots.
Results:
Garmin recorded 990 steps/day more than the ActiGraph with good agreement (ICC = 0.81, limits of agreement [LoA] -1123 to 3104 steps/day). For AEE, the Garmin reported 41.8 kcal/day lower values, with poor agreement (ICC = 0.29, LoA -582.9 to 499.4 kcal/day). MVPA showed the largest discrepancy, with the Garmin recording 23 minutes/day less and poor agreement (ICC = 0.17, LoA -86.7 to 40.6 minutes/day). Bland-Altman plots indicated proportional bias across all metrics.
Conclusions:
The Garmin Forerunner 55 demonstrated good agreement for daily step count but poor agreement for AEE and MVPA compared with the ActiGraph wGT3X in older adults with low activity levels. Consumer devices such as the Garmin Forerunner may be suitable for long-term monitoring of step-based metrics at the group level, but intensity-based measures should be interpreted with caution. Clinical Trial: clinicaltrials.gov, NCT06122441, (registered prospectively 2023-10-26)
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.