Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Currently submitted to: JMIRx Med

Date Submitted: Jun 19, 2026
Open Peer Review Period: Jun 30, 2026 - Aug 25, 2026
(closed for review but you can still tweet)

NOTE: This is an unreviewed Preprint

Warning: This is a unreviewed preprint (What is a preprint?). Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn (a note "no longer under consideration" will appear above).

Peer review me: Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period (in this case, a "Peer Review Me" button to sign up as reviewer is displayed above). All preprints currently open for review are listed here. Outside of the formal open peer-review period we encourage you to tweet about the preprint.

Citation: Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author).

Final version: If our system detects a final peer-reviewed "version of record" (VoR) published in any journal, a link to that VoR will appear below. Readers are then encourage to cite the VoR instead of this preprint.

Settings: If you are the author, you can login and change the preprint display settings, but the preprint URL/DOI is supposed to be stable and citable, so it should not be removed once posted.

Submit: To post your own preprint, simply submit to any JMIR journal, and choose the appropriate settings to expose your submitted version as preprint.

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Expert in Ultrasound Skills: Feasibility of an IMU-video platform to describe technical profiles during focused cardiac ultrasound. Pilot study

  • Felipe Riquelme Sr; 
  • Sofia Rivera; 
  • Maria Francisca Seydewitz; 
  • Barbara Lara Hernandez; 
  • David Gonzalo Acuña Ramirez

ABSTRACT

Background:

Focused cardiac ultrasound (FoCUS) is operator dependent and requires coordinated probe manipulation, image interpretation and iterative visual feedback. Existing assessment approaches often emphasize final image quality or expert rating.

Objective:

We developed Expert in Ultrasound Skills (EXUS) , a platform that synchronizes transducer-mounted inertial measurement unit (IMU) data with ultrasound video, and evaluated its technical feasibility during FoCUS acquisition.

Methods:

This observational pilot study included 6 operators performing two repetitions of a four-view FoCUS protocol, yielding 12 analytical sessions and 48 planned acquisitions. Feasibility was defined by acquisition completion, video availability, start/stop events, fused IMU-video windows, temporal coverage, complete human label entries and IMU integrity. A 100-image Likert rating task was used to summarize pairwise inter-rater agreement for still-frame image quality assessment.

Results:

All 48 planned acquisitions were completed with video, start/stop events, fused windows and complete human label entries. Temporal coverage was at least 90% in 47/48 acquisitions. IMU integrity endpoints exceeded the 80% threshold: 43/48 acquisitions had no extreme IMU-derived artifact, 43/48 had no active-segment IMU restart and 44/48 had no complete motion flatline. Mean pairwise exact agreement for the Likert task was 38.9%, with mean quadratic-weighted Cohen's kappa of 0.564. Post hoc profiles varied across duration, visual quality, mechanical load and motor efficiency.

Conclusions:

EXUS was technically feasible for synchronized IMU-video capture during FoCUS. The pilot supports multimodal acquisition data as a way to describe technical profiles and generate formative feedback hypotheses, but the post hoc indices are not validated competency measures.


 Citation

Please cite as:

Riquelme F Sr, Rivera S, Seydewitz MF, Lara Hernandez B, Acuña Ramirez DG

Expert in Ultrasound Skills: Feasibility of an IMU-video platform to describe technical profiles during focused cardiac ultrasound. Pilot study

JMIR Preprints. 19/06/2026:105099

DOI: 10.2196/preprints.105099

URL: https://preprints.jmir.org/preprint/105099

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.