Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Currently submitted to: Journal of Medical Internet Research

Date Submitted: May 18, 2026
Open Peer Review Period: Aug 21, 2026 - Oct 21, 2026
(closed for review but you can still tweet)

NOTE: This is an unreviewed Preprint

Warning: This is a unreviewed preprint (What is a preprint?). Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn (a note "no longer under consideration" will appear above).

Peer review me: Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period (in this case, a "Peer Review Me" button to sign up as reviewer is displayed above). All preprints currently open for review are listed here. Outside of the formal open peer-review period we encourage you to tweet about the preprint.

Citation: Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author).

Final version: If our system detects a final peer-reviewed "version of record" (VoR) published in any journal, a link to that VoR will appear below. Readers are then encourage to cite the VoR instead of this preprint.

Settings: If you are the author, you can login and change the preprint display settings, but the preprint URL/DOI is supposed to be stable and citable, so it should not be removed once posted.

Submit: To post your own preprint, simply submit to any JMIR journal, and choose the appropriate settings to expose your submitted version as preprint.

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Prompt-engineering improves clinical safety of large language models for opioid equipotency conversion

  • Tanya M Marton; 
  • David Corpman; 
  • Lytia Lai; 
  • Rodney A Gabriel; 
  • Yian Chen

ABSTRACT

Background:

Large language models (LLMs) are increasingly used in medical education and clinical decision-making, but their reliability in high-risk medication dosing remains unclear. Opioid rotation is a common task requiring precise calculations where errors may result in overdose or inadequate pain relief.

Objective:

The objectives of this study are to assess the performance of commercial LLMS in opioid conversions and further analyze types of errors in process.

Methods:

Thirteen LLMs were tested using an API-based framework to ensure independent queries across trials. First, fictional clinical scenarios were tested to simulate real-world clinical situations involving opioid rotation; to test the effects of changes in wording, scenarios were revised into 4 “vignettes” showing the same clinical situation. Next, opioid pairs were tested with a random-dose paradigm across a clinically-pertinent range (5-120 mg daily morphine equivalents). LLM outputs were compared with expected values derived from reference standards. Accuracy was assessed using predefined safety thresholds: tight accuracy (0.85–1.15x expected dose) and broad accuracy (0.6–1.7x). We tested models naively and with prompts augmented with reference tables and unit explanations.

Results:

Naive models generally exhibited low tight-range accuracy across opioid pairs. For any given opioid pair, each model would consistently produce similar incorrect conversion ratios despite wide variability across opioid pairs and language models. Vignette wording changes accounted for 76% of within-scenario response variance. Reference-based prompt augmentation significantly improved performance, with over half of models achieving high proportions of conversions within tight accuracy for morphine-equivalent conversions.

Conclusions:

While commercial LLMs demonstrated variable accuracy in the native state, prompt augmentation significantly improved their performance.


 Citation

Please cite as:

Marton TM, Corpman D, Lai L, Gabriel RA, Chen Y

Prompt-engineering improves clinical safety of large language models for opioid equipotency conversion

JMIR Preprints. 18/05/2026:101566

DOI: 10.2196/preprints.101566

URL: https://preprints.jmir.org/preprint/101566

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.