Development and Psychometric Validation of a Usability Instrument Based on ISO 25010 for Electronic Health Record Systems in Peruvian Health Care Settings: Methodological Study

Mamani-Pari D, Peñaloza-Hualpa AF, Humpiri-Flores ME, Gutierrez-Quispe E, Otazu-Luque JE

Development and Psychometric Validation of a Usability Instrument Based on ISO 25010 for Electronic Health Record Systems in Peruvian Health Care Settings: Methodological Study

JMIR Hum Factors 2026;13:e81377

DOI: 10.2196/81377

PMID: 42172648

Development and Psychometric Validation of a Usability Instrument Based on ISO 25010 for Electronic Health Record Systems in Peruvian Healthcare Settings: A Methodological Study

  • David Mamani-Pari; 
  • Alex Froilan Peñaloza-Hualpa; 
  • Milton Edward Humpiri-Flores; 
  • Eder Gutierrez-Quispe; 
  • Jorge Eddy Otazu-Luque

ABSTRACT

Background:

The usability of electronic health record (EHR) systems is crucial for patient safety and clinical efficiency, particularly in developing countries such as Peru, where challenges in implementing these technologies persist.

Objective:

To develop and validate an instrument based on the ISO 25010 standard to evaluate the usability of the EHR module, integrated with the requirements of the Peruvian Technical Health Standard (NTS).

Methods:

A methodological study was conducted in three phases: (1) Development of the instrument by integrating 23 items organized into seven usability dimensions; (2) Content validation with 10 experts using Aiken's V coefficient; and (3) Psychometric validation with 115 users using confirmatory factor analysis and reliability calculation. The study evaluated a HCE module implemented in a Peruvian health institution.

Results:

The instrument demonstrated excellent psychometric properties: content validity (V=0.95), model fit (CFI=1.000, TLI=1.001), and high reliability (α=0.968). Overall usability was perceived as "very high" (81.7%) and "high" (18.3%). The module met 80% of the NTS requirements. Certain differences were identified, but they were not significant between clinical and administrative professionals in terms of perceived usability.

Conclusions:

This study provides the first validated instrument in Spanish for evaluating the usability of information systems that integrates ISO 25010, SUS, and other theoretical foundations. The results highlight the importance of considering both international standards and local regulatory requirements (NTS) in the design of digital health systems. The instrument is applicable in Spanish-speaking contexts and can serve as a reference for future usability evaluations in the region.


 Citation

Please cite as:

Mamani-Pari D, Peñaloza-Hualpa AF, Humpiri-Flores ME, Gutierrez-Quispe E, Otazu-Luque JE

Development and Psychometric Validation of a Usability Instrument Based on ISO 25010 for Electronic Health Record Systems in Peruvian Health Care Settings: Methodological Study

JMIR Hum Factors 2026;13:e81377

DOI: 10.2196/81377

PMID: 42172648

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.