Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Research Protocols

Date Submitted: May 16, 2017
Open Peer Review Period: May 19, 2017 - Aug 9, 2017
Date Accepted: Oct 30, 2017
(closed for review but you can still tweet)

The final, peer-reviewed published version of this preprint can be found here:

Daily Activity Measured With Wearable Technology as a Novel Measurement of Treatment Effect in Patients With Coronary Microvascular Dysfunction: Substudy of a Randomized Controlled Crossover Trial

Birkeland K, Khandwalla RM, Kedan I, Shufelt CL, Mehta PK, Minissian MB, Wei J, Handberg EM, Thomson LE, Berman DS, Petersen JW, Anderson RD, Cook-Wiens G, Pepine CJ, Bairey Merz CN

Daily Activity Measured With Wearable Technology as a Novel Measurement of Treatment Effect in Patients With Coronary Microvascular Dysfunction: Substudy of a Randomized Controlled Crossover Trial

JMIR Res Protoc 2017;6(12):e255

DOI: 10.2196/resprot.8057

PMID: 29263019

PMCID: 5752966

Daily Activity Measured With Wearable Technology as a Novel Measurement of Treatment Effect in Patients With Coronary Microvascular Dysfunction: Substudy of a Randomized Controlled Crossover Trial

  • Kade Birkeland; 
  • Raj M Khandwalla; 
  • Ilan Kedan; 
  • Chrisandra L Shufelt; 
  • Puja K Mehta; 
  • Margo B Minissian; 
  • Janet Wei; 
  • Eileen M Handberg; 
  • Louise EJ Thomson; 
  • Daniel S Berman; 
  • John W Petersen; 
  • R David Anderson; 
  • Galen Cook-Wiens; 
  • Carl J Pepine; 
  • C Noel Bairey Merz

ABSTRACT

Background:

Digital wearable devices provide a “real-world” assessment of physical activity and quantify intervention-related changes in clinical trials. However, the value of digital wearable device-recorded physical activity as a clinical trial outcome is unknown.

Objective:

Because late sodium channel inhibition (ranolazine) improves stress laboratory exercise duration among angina patients, we proposed that this benefit could be quantified and translated during daily life by measuring digital wearable device-determined step count in a clinical trial.

Methods:

We conducted a substudy in a randomized, double-blinded, placebo-controlled, crossover trial of participants with angina and coronary microvascular dysfunction (CMD) with no obstructive coronary artery disease to evaluate the value of digital wearable device monitoring. Ranolazine or placebo were administered (500-1000 mg twice a day) for 2 weeks with a subsequent 2-week washout followed by crossover to ranolazine or placebo (500-1000 mg twice a day) for an additional 2 weeks. The outcome of interest was within-subject difference in Fitbit Flex daily step count during week 2 of ranolazine versus placebo during each treatment period. Secondary outcomes included within-subject differences in angina, quality of life, myocardial perfusion reserve, and diastolic function.

Results:

A total of 43 participants were enrolled in the substudy and 30 successfully completed the substudy for analysis. Overall, late sodium channel inhibition reduced within-subject daily step count versus placebo (mean 5757 [SD 3076] vs mean 6593 [SD 339], P=.01) but did not improve angina (Seattle Angina Questionnaire-7 [SAQ-7]) (P=.83). Among the subgroup with improved angina (SAQ-7), a direct correlation with increased step count (r=.42, P=.02) was observed.

Conclusions:

We report one of the first studies to use digital wearable device-determined step count as an outcome variable in a placebo-controlled crossover trial of late sodium channel inhibition in participants with CMD. Our substudy demonstrates that late sodium channel inhibition was associated with a decreased step count overall, although the subgroup with angina improvement had a step count increase. Our findings suggest digital wearable device technology may provide new insights in clinical trial research. Trial Registration: Clinicaltrials.gov NCT01342029; https://clinicaltrials.gov/ct2/show/NCT01342029 (Archived by WebCite at http://www.webcitation.org/6uyd6B2PO)


 Citation

Please cite as:

Birkeland K, Khandwalla RM, Kedan I, Shufelt CL, Mehta PK, Minissian MB, Wei J, Handberg EM, Thomson LE, Berman DS, Petersen JW, Anderson RD, Cook-Wiens G, Pepine CJ, Bairey Merz CN

Daily Activity Measured With Wearable Technology as a Novel Measurement of Treatment Effect in Patients With Coronary Microvascular Dysfunction: Substudy of a Randomized Controlled Crossover Trial

JMIR Res Protoc 2017;6(12):e255

DOI: 10.2196/resprot.8057

PMID: 29263019

PMCID: 5752966

Per the author's request the PDF is not available.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.