Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Human Factors

Date Submitted: Aug 29, 2024
Date Accepted: Jan 5, 2025

The final, peer-reviewed published version of this preprint can be found here:

An Explainable AI Application (AF’fective) to Support Monitoring of Patients With Atrial Fibrillation After Catheter Ablation: Qualitative Focus Group, Design Session, and Interview Study

She WJ, Siriaraya P, Iwakoshi H, Kuwahara N, Senoo K

An Explainable AI Application (AF’fective) to Support Monitoring of Patients With Atrial Fibrillation After Catheter Ablation: Qualitative Focus Group, Design Session, and Interview Study

JMIR Hum Factors 2025;12:e65923

DOI: 10.2196/65923

PMID: 39946707

PMCID: 11888073

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Development of AF’fective: an Explainable AI Application to Support Remote Monitoring of Atrial Fibrillation Patients After Catheter Ablation

  • Wan Jou She; 
  • Panote Siriaraya; 
  • Hibiki Iwakoshi; 
  • Noriaki Kuwahara; 
  • Keitaro Senoo

ABSTRACT

Background:

The opaque nature of AI algorithms has led to distrust in medical contexts, particularly in treating and monitoring Atrial Fibrillation (AF). While previous studies in explainable AI show potential to address this, they often focus solely on ECG factors and lack real-life field insights.

Objective:

We address this gap by integrating extra empirically validated risk factors into the system and involving cardiologists in co-designing and evaluating the approach using real-life patient cases and data.

Methods:

We conducted a 3-stage iterative design with 23 cardiologists to co-design, evaluate, and pilot an explainable AI application. The first stage identified four doctor personas and seven explainable strategies, which were reviewed in the second stage. Four strategies were selected as highly effective and feasible for pilot deployment. A Progressive Web Application (PWA) was then developed based on these four strategies and tested by cardiologists in the third stage.

Results:

The final PWA prototype received above-average UX evaluations and excelled in motivating doctors' intention to use it, thanks to its ease of use, reliable information, and explainable functionality. We also discussed in-depth field insights from cardiologists using the system in clinical contexts.

Conclusions:

Our study identified effective explainable strategies, emphasized curating actionable factors and setting correct expectations, and suggested that many insights could be applicable to other disease care contexts, paving the way for future real-life clinical evaluations.


 Citation

Please cite as:

She WJ, Siriaraya P, Iwakoshi H, Kuwahara N, Senoo K

An Explainable AI Application (AF’fective) to Support Monitoring of Patients With Atrial Fibrillation After Catheter Ablation: Qualitative Focus Group, Design Session, and Interview Study

JMIR Hum Factors 2025;12:e65923

DOI: 10.2196/65923

PMID: 39946707

PMCID: 11888073

Per the author's request the PDF is not available.