Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR mHealth and uHealth

Date Submitted: May 10, 2024
Date Accepted: Apr 16, 2025

The final, peer-reviewed published version of this preprint can be found here:

A New Wearable System for Personal Air Pollution Exposure Estimation: Pilot Observational Study

Bernasconi S, Angelucci A, Rossi A, Aliverti A

A New Wearable System for Personal Air Pollution Exposure Estimation: Pilot Observational Study

JMIR Mhealth Uhealth 2025;13:e60426

DOI: 10.2196/60426

PMID: 40614107

PMCID: 12248256

A New Wearable System for Personal Air Pollution Exposure Estimation: Pilot Observational Study

  • Sara Bernasconi; 
  • Alessandra Angelucci; 
  • Andrea Rossi; 
  • Andrea Aliverti

ABSTRACT

Background:

Personal air pollution exposure (PAPE) is the product of pollutant concentration and minute ventilation V’????. Standard exposure techniques do not address the space-time variability of air pollution, both indoor and outdoor, and the intra and inter subject variability in V’????.

Objective:

This study introduces a wearable system for Personal Air Pollution Exposure (PAPE) evaluation, computed as pollutant concentration multiplied by minute ventilation V’????.

Methods:

The system, a body sensor network capturing physiological (heart and respiratory rate) and environmental data, including health-affecting pollutants (PM1, PM2.5, PM10, CO2, CO, tVOC, NO2), was tested in a 4.5 km walk in Milan by 20 healthy volunteers. Physiological measurements and estimations were used in a V’???? model.

Results:

Significant pollutant concentration differences between morning and afternoon, and among acquisition points were found. Respiratory rates varied among subjects and acquisition points. PAPE to PM2.5, using tabulated V’???? and fixed station concentrations, was 2.96 mg higher than with the proposed system.

Conclusions:

This system, providing high resolution spatiotemporal personal exposure data, may enhance epidemiological studies with individualized exposure insights.


 Citation

Please cite as:

Bernasconi S, Angelucci A, Rossi A, Aliverti A

A New Wearable System for Personal Air Pollution Exposure Estimation: Pilot Observational Study

JMIR Mhealth Uhealth 2025;13:e60426

DOI: 10.2196/60426

PMID: 40614107

PMCID: 12248256

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.