Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Diabetes

Date Submitted: Apr 24, 2024
Open Peer Review Period: Apr 24, 2024 - Jun 19, 2024
Date Accepted: Jul 6, 2024
(closed for review but you can still tweet)

The final, peer-reviewed published version of this preprint can be found here:

Implementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study

Antaki F, Hammana I, Tessier MC, Boucher A, David Jetté ML, Beauchemin C, Hammamji K, Ong AY, Rhéaume MA, Gauthier D, Harissi-Dagher M, Keane PA, Pomp A

Implementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study

JMIR Diabetes 2024;9:e59867

DOI: 10.2196/59867

PMID: 39226095

PMCID: 11408885

Implementation of Artificial Intelligence-Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: A Prospective Validation Study

  • Fares Antaki; 
  • Imane Hammana; 
  • Marie-Catherine Tessier; 
  • Andrée Boucher; 
  • Maud Laurence David Jetté; 
  • Catherine Beauchemin; 
  • Karim Hammamji; 
  • Ariel Yuhan Ong; 
  • Marc-André Rhéaume; 
  • Danny Gauthier; 
  • Mona Harissi-Dagher; 
  • Pearse A. Keane; 
  • Alfons Pomp

ABSTRACT

Background:

Diabetic retinopathy (DR) affects about 25% of people with diabetes in Canada. Early detection of DR is essential for preventing vision loss.

Objective:

We evaluated the real-world performance of an artificial intelligence (AI) system that analyses fundus images for DR screening in a Quebec tertiary care centre.

Methods:

We prospectively recruited adult patients with diabetes at the Centre hospitalier de l’Université de Montréal (CHUM) in Montreal, Quebec, Canada. Patients underwent dual-pathway screening: first by the CARA AI system (index test), then by standard ophthalmological examination (reference standard). We measured the AI system's sensitivity and specificity for detecting referable disease at the patient level, along with its performance for detecting any retinopathy and diabetic macular edema (DME) at the eye level, and potential cost savings.

Results:

The study included 115 patients. CARA demonstrated a sensitivity of 87.5% (95% CI: 71.9-95.0) and specificity of 66.2% (95% CI: 54.3-76.3) for detecting referable disease at the patient level. For any retinopathy detection at the eye level, CARA showed 88.2% sensitivity (95% CI: 76.6-94.5) and 71.4% specificity (95% CI: 63.7-78.1). For DME detection, CARA had 100% sensitivity (95% CI: 64.6-100) and 81.9% specificity (95% CI: 75.6-86.8). Potential yearly savings from implementing CARA at the CHUM were estimated at CAD 245,635 considering 5,000 diabetic patients.

Conclusions:

Our study indicates that integrating a semi-automated AI system for DR screening demonstrates high sensitivity for detecting referable disease in a real-world setting. This system has the potential to improve screening efficiency and reduce costs at the CHUM.


 Citation

Please cite as:

Antaki F, Hammana I, Tessier MC, Boucher A, David Jetté ML, Beauchemin C, Hammamji K, Ong AY, Rhéaume MA, Gauthier D, Harissi-Dagher M, Keane PA, Pomp A

Implementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study

JMIR Diabetes 2024;9:e59867

DOI: 10.2196/59867

PMID: 39226095

PMCID: 11408885

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.