Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Formative Research

Date Submitted: Oct 16, 2023
Date Accepted: Nov 24, 2024

The final, peer-reviewed published version of this preprint can be found here:

Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study

Davis-Wilson HC, Hegarty-Craver M, Gaur P, Boyce M, Holt JR, Preble E, Eckhoff R, Li L, Walls H, Dausch D, Temple D

Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study

JMIR Form Res 2025;9:e53645

DOI: 10.2196/53645

PMID: 39993288

PMCID: 11894354

Effects of Missing Data on Heart Rate Variability Measured from a Smartwatch: Exploratory Observational Study

  • Hope C. Davis-Wilson; 
  • Meghan Hegarty-Craver; 
  • Pooja Gaur; 
  • Matthew Boyce; 
  • Jonathan R Holt; 
  • Edward Preble; 
  • Randy Eckhoff; 
  • Lei Li; 
  • Howard Walls; 
  • David Dausch; 
  • Dorota Temple

ABSTRACT

Background:

Measuring heart rate variability (HRV) via wearable photoplethysmography (PPG) sensors like smartwatches is gaining popularity for monitoring of many health conditions. However, missing data caused by insufficient wear compliance or signal quality can degrade the performance of health metric or algorithm calculations. Research is needed on how to best account for missing data and to measure data validity to assess the accuracy of metrics derived from wearable sensor data.

Objective:

To evaluate the influence of missing data on HRV metrics collected from smartwatches both at rest and during physical activity in real-world settings and to evaluate HRV agreement and consistency between wearable PPG and gold standard wearable electrocardiogram (ECG) sensors in real-world settings.

Methods:

Healthy participants were outfitted with a smartwatch with a PPG sensor that collected high resolution inter beat interval data to wear continuously (day and night) for up to 12 months. New data sets were created with various amount of missing data and then compared to the original (reference) data sets. 5 min windows of each HRV metric (median RR interval [RR], standard deviation of the RR interval [STDRR], root mean square error of the RR interval [RMSDRR], low frequency power [LF], high frequency power [HF], and the ratio of LF to HF power [LF/HF]) were compared between the reference dataset and the missing data sets (~10%, ~20%, ~35%, and ~60% missing data). HRV metrics calculated from the PPG sensor were compared to HRV metrics calculated from a chest-worn ECG sensor.

Results:

Median RR, STDRR, and RMSDRR remain stable at rest until at least ~35% data degradation (P < 0.05). LF, HF, and LF/HF are less resilient to missing data both at rest and during light activity and are unstable even at ~10% data degradation (P < 0.05). Median RR intervals calculated from PPG sensors had moderate agreement (intraclass correlation coefficient [ICC] = 0.585) and consistency (ICC = 0.589) and LF had moderate consistency (ICC = 0.545) with ECG sensors. Other HRV metrics demonstrated poor agreement (ICC = 0.071 – 0.472).

Conclusions:

This study describes methodology for the extraction of HRV metrics from PPG sensor data that resulted in stable and valid metrics while utilizing the least amount of available data. While smartwatches containing PPG sensors are valuable for remote monitoring of patients, future work is needed to identify best practices for using these sensors to evaluate HRV in medical settings.


 Citation

Please cite as:

Davis-Wilson HC, Hegarty-Craver M, Gaur P, Boyce M, Holt JR, Preble E, Eckhoff R, Li L, Walls H, Dausch D, Temple D

Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study

JMIR Form Res 2025;9:e53645

DOI: 10.2196/53645

PMID: 39993288

PMCID: 11894354

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.