Evaluation of the effectiveness of advanced technology clinical simulation in improving the capability of Australian paramedics to deliver high quality patient care: a pre-post intervention study
ABSTRACT
Background:
Emergency medical services attend out-of-hospital cardiac arrest (OHCA) all across Australia. Resuscitation by emergency medical services is attempted in nearly half of all cases. However, resuscitation skills can degrade over time without adequate exposure, which negatively impacts patient survival. In locations where paramedic exposure to OHCA is low, other avenues for ensuring resuscitation skills are maintained should be put in place. Simulation-based training via resuscitation manikins offers a potential solution for maintaining paramedic clinical practice skills.
Objective:
To examine the effectiveness of advanced technology clinical simulation manikins in improving the demonstrable capability of paramedics to deliver high quality patient care, as measured by External Cardiac Compression performance (ECC).
Methods:
A pre-post intervention study without a control group. Data were collected at the start of the manikin training forum (Baseline); immediately following the training forum (Time 2); and 6 to 11 months after the training forum (Time 3). The study was conducted in paramedics from 95 NSW Ambulance locations (75 regional locations, 20 metropolitan locations). Eligible participants were paramedics who were employed by NSW Ambulance (n=95; 100% consent rate). As part of the intervention, paramedics attended a training session on use of advanced technology simulation manikins. Manikins were then deployed to locations for further use. The main outcome measures was an overall compression score was automatically recorded and calculated by the simulator manikin in two-minute cycles. This score was derived from compressions with correct hand position, adequate depth, fully released, and adequate rate.
Results:
ECC compression scores were on average 95% or above at all time points, suggesting high performance. No significant differences over time (p>0.05) were identified for overall ECC performance score.
Conclusions:
Training and deployment of simulator manikins did not significantly change paramedic’s ECC performance. The high baseline performance (ceiling effect) of paramedics in this sample may have prevented the potential increase in skills and performance.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.