Development and Performance of a Web-Based Tool to Adjust Urine Toxicology Testing Frequency: Retrospective Study

Chapman KB, Pas MM, Abrar D, Day W, Vissers KC, van Helmond N

Development and Performance of a Web-Based Tool to Adjust Urine Toxicology Testing Frequency: Retrospective Study

JMIR Med Inform 2020;8(4):e16069

DOI: 10.2196/16069

PMID: 32319958

PMCID: 7203611

Development and Performance of a Web-Based Application to Adjust Urine Toxicology Testing Frequency

  • Kenneth B Chapman; 
  • Martijn M Pas; 
  • Diana Abrar; 
  • Wesley Day; 
  • Kris C Vissers; 
  • Noud van Helmond

ABSTRACT

Background:

Guidelines recommend regular urine drug testing (UDT) in patients on chronic opioid therapy (COT) to improve compliance. Guidelines also recommend more frequent testing in patients at high risk of opioid misuse, but there is no consensus on how to identify high-risk patients and on the absolute testing frequency. Using previously described clinical risk factors of opioid misuse, we developed a web-based tool to adjust UDT frequency in patients on COT.

Objective:

To evaluate a risk stratification tool to adjust UDT frequency in patients on COT.

Methods:

Patients were stratified using an algorithm based on readily available clinical risk factors into categories of presumed low, moderate, high, and high+ risk. The algorithm was integrated in a website to facilitate adoption across practice sites. To test the performance of this algorithm we performed a retrospective analysis in patients on COT. The primary outcome was compliance with the prescribed COT, defined by UDT results consistent with the prescribed COT.

Results:

1056 urine drug tests were performed in 320 included patients. An inconsistent UDT result was registered in 52 patients (16%). The incidence of inconsistent UDT differed across the risk tool categories from 4% (low risk), to 18% (moderate risk), to 18% (high risk), to 23% (high+ risk), respectively. Regression revealed that the moderate (OR: 3.8, 95%-CI: 1.3–11.4, P=0.02), high risk (OR: 3.4, 95%-CI: 1.1–10.5, P=0.04), and high-risk+ (OR: 4.4, 95%-CI: 1.2–16.4, P=0.03) category were associated with an increased risk of having more inconsistent UDT results vs. the low-risk category.

Conclusions:

The tool appears to correctly stratify patients on COT at higher risk of presenting with UDT results inconsistent with the prescribed therapy.


 Citation

Please cite as:

Chapman KB, Pas MM, Abrar D, Day W, Vissers KC, van Helmond N

Development and Performance of a Web-Based Tool to Adjust Urine Toxicology Testing Frequency: Retrospective Study

JMIR Med Inform 2020;8(4):e16069

DOI: 10.2196/16069

PMID: 32319958

PMCID: 7203611

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.