Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Accepted for/Published in: JMIR Medical Informatics

Date Submitted: Aug 17, 2026
Date Accepted: Oct 16, 2026

The final, peer-reviewed published version of this preprint can be found here:

Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study

Huang JL, Li LJ, Wang ML, Zhu JQ, Dou LZ, Liu YM, Zhao YD, Zhang X, Ni XG

Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study

JMIR Med Inform 2026;14:e109811

DOI: 10.2196/109811

PMID: 43097400

Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study

  • Jie-Lin Huang; 
  • Li-Juan Li; 
  • Mei-Ling Wang; 
  • Ji-Qing Zhu; 
  • Li-Zhou Dou; 
  • Yu-Meng Liu; 
  • Yu-Da Zhao; 
  • Xue Zhang; 
  • Xiao-Guang Ni

ABSTRACT

Background:

Pathology-labeled optical narrow-band imaging (NBI) is difficult to assemble at scale, limiting model development for laryngeal lesion classification. Translating white-light imaging (WLI) into virtual NBI (Vir-NBI) could enlarge target-style training sets without NBI acquisition. However, deterministic translation creates neither new patients nor new pathology information. Although Vir-NBI can appear clinically plausible and assist image interpretation, whether it adds training value beyond its source WLI or reduces dependence on labeled real NBI remains unknown.

Objective:

To determine whether Vir-NBI pretraining reduces real-NBI label requirements and improves multicenter classification compared with matched WLI pretraining.

Methods:

We performed a multicenter model development and validation study. Pathology-labeled WLI images were translated one-to-one using a previously developed, frozen region-of-interest–guided CycleGAN. WLI- and Vir-NBI–pretrained ResNet-50 strategies used identical source patients, labels, architecture, real-NBI fine-tuning subsets, and evaluation cohorts; only source-image representation differed. The primary outcome was the Vir-NBI–minus-WLI image-level area under the receiver operating characteristic curve (AUC) difference, equally averaged across 2 retrospective external centers using paired patient-clustered bootstrap. Label efficiency across 10–100 real-NBI patients used 5 nested patient sequences crossed with 5 seeds. Supporting analyses separated translation and fine-tuning effects, examined representations and lesion attribution, and included quality assessment by 3 clinicians. A biopsy-indicated cohort was prospectively enrolled after model and threshold lock and evaluated without retraining, recalibration, threshold modification, or disclosure of predictions to clinicians.

Results:

The source cohort included 1245 patients and 8476 WLI–Vir-NBI pairs. External image-level macroaverage AUC was 0.8056 with WLI pretraining and 0.7867 with Vir-NBI pretraining (difference −0.0190, 95% CI −0.0473 to 0.0079; P=.168). The deficit was greatest when labels were scarcest: at 10 real-NBI patients, patient-level AUC was 0.8626 versus 0.7881 (difference −0.0745, 95% CI −0.1261 to −0.0252; Holm-adjusted P=.018). The difference narrowed to −0.0140 at 100 patients, but integrated performance over 10–100 patients remained lower with Vir-NBI pretraining (difference −0.0397, 95% CI −0.0799 to −0.0022; Holm-adjusted P=.038). Without real-NBI fine-tuning, Vir-NBI direct transfer reduced patient-level AUC by 0.0763 (Holm-adjusted P=.002); fine-tuning increased AUC by 0.0786 within the Vir-NBI pathway (Holm-adjusted P=.001). In prospective validation of 138 patients, patient-level AUCs were similar (0.8460 vs 0.8445; P=.962), but sensitivity was lower after Vir-NBI pretraining at locked thresholds (0.9091 vs 0.8182; Holm-adjusted P=.007). All 300 clinician ratings met the clinical-plausibility threshold, yet no quality–utility association remained significant after multiplicity correction.

Conclusions:

Clinically plausible Vir-NBI did not reduce the labeled real NBI required for classifier development beyond matched WLI pretraining. Visual or reader-facing utility should not be assumed to imply incremental training information. Synthetic target-style images derived from existing labeled images should be evaluated against the source data they re-express. Synthetic imaging should therefore be judged against the clinical problem it is intended to solve.


 Citation

Please cite as:

Huang JL, Li LJ, Wang ML, Zhu JQ, Dou LZ, Liu YM, Zhao YD, Zhang X, Ni XG

Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study

JMIR Med Inform 2026;14:e109811

DOI: 10.2196/109811

PMID: 43097400

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.