Previously submitted to: Journal of Medical Internet Research (no longer under consideration since Nov 19, 2026)
Date Submitted: Mar 12, 2026
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
A Human-Centered Digital Decision Pathway for COPD Noninvasive Ventilation Adjustment: Design and Development Using the Double Diamond Framework
ABSTRACT
Background:
Noninvasive ventilation is a cornerstone intervention for managing acute exacerbations in patients with chronic obstructive pulmonary disease. However, current practice for adjusting NIV parameters in COPD remains largely experience-based, with limited standardized guidance, potentially leading to delays or inconsistencies in treatment. The Double Diamond model, a human-centered design methodology, has been widely adopted in service innovation and digital health. Its structured process—comprising problem discovery, definition, development, and delivery—has shown promise in areas such as mental health and diabetes care. Nevertheless, its application to the development of clinical decision support systems for NIV titration in COPD patients remains unexplored.
Objective:
This study aimed to develop and validate a human-centered clinical decision support system (CopdnivDss) to assist in the titration of NIV parameters for COPD patients. The system was designed to generate a visual, rule-based decision pathway grounded in the Double Diamond framework.
Methods:
Using the four-phase Double Diamond methodology, we developed the CopdnivDss system through iterative, user-centered processes. In the Discover phase, workflow observations and semi-structured interviews with co-designers were conducted to identify key pain points and decision barriers. During the Define phase, qualitative themes were translated into explicit system requirements and used to refine decision variables extracted from clinical guidelines and retrospective datasets. In the Develop phase, we constructed a rule-based NIV titration algorithm and developed iterative interface prototypes for decision support. In the Deliver phase, the system was prospectively validated using 958 COPD patient records to evaluate improvements in oxygen saturation. Usability was assessed using the System Usability Scale and a decision concordance test among clinicians.
Results:
The CopdnivDss decision pathways covered over 85% of common NIV adjustment scenarios. User feedback indicated reduced cognitive load and improved workflow support. Implementation of the system resulted in a statistically significant improvement in SpO₂ levels (P<.001), with greater benefit observed among junior clinicians.
Conclusions:
The implementation of CopdnivDss demonstrates the feasibility of applying the Double Diamond framework to the development of structured decision pathways for NIV parameter adjustment in COPD patients. The system not only improved the effectiveness of ventilator titration but also enhanced clinical confidence among junior physicians. This study provides preliminary evidence for the potential of co-designed digital tools in supporting personalized ventilation management in patients with COPD. Clinical Trial: None
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.