Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Previously submitted to: JMIR Biomedical Engineering (no longer under consideration since Aug 19, 2025)

Date Submitted: Dec 13, 2024

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Development of a Step Prototype for Functional Capacity Tests: Technological Advancement for Rehabilitation.

  • Renan Shida Marinho; 
  • Luciana Di Thommazo -Luporini; 
  • Aldair Darlan Santos -de-Araújo; 
  • Matheus Borghi Ricardo De Oliveira; 
  • Izadora Moraes Dourado; 
  • Cássia da Luz Goulart; 
  • Daniel Braatz Antunes de Almeida Moura; 
  • Andre Ditomaso; 
  • Daniela Bassi -Dibai; 
  • Meliza Goi Roscani; 
  • Audrey Borghi-Silva

ABSTRACT

Background:

In the field of health engineering, the development of portable ergometric equipment is essential for physical assessment and rehabilitation. These devices are used in clinical and research settings for diagnosis, exercise prescription, and monitoring of signs and symptoms, allowing for the measurement of individuals' functional capacity and cardiorespiratory fitness.

Objective:

To develop a step prototype that meets the testing requirements proposed in the literature, integrated with software to facilitate data evaluation and interpretation.

Methods:

Functional and ergonomic requirements were considered in the creation of the prototype to meet the demands of healthcare professionals and patients. This resulted in a patent registered with the National Institute of Industrial Property (INPI) under number BR2020150006034, with integration into an Android operating system. The prototype development process included the following stages: (1) material design; (2) assembly of the ergometer; (3) flexibility and adaptability; (4) technology integration; (5) usability and safety.

Results:

The step prototype was developed with an adjustable height in four levels, ranging from 15 cm to 30 cm, and has an overall width of 80 cm. After testing, the internal side of the upper contralateral face of the step base contains a USB card that stores the test data.

Conclusions:

The developed step can serve as an effective tool for applying various step test protocols, featuring automatic step counting and time recording.


 Citation

Please cite as:

Marinho RS, -Luporini LDT, -de-Araújo ADS, Ricardo De Oliveira MB, Dourado IM, Goulart CdL, de Almeida Moura DBA, Ditomaso A, -Dibai DB, Roscani MG, Borghi-Silva A

Development of a Step Prototype for Functional Capacity Tests: Technological Advancement for Rehabilitation.

JMIR Preprints. 13/12/2024:69872

DOI: 10.2196/preprints.69872

URL: https://preprints.jmir.org/preprint/69872

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.