Background:
Crohn's disease (CD), a complex member of the inflammatory bowel disease spectrum, is characterized by the diversity and skipping distribution of intestinal mucosal lesions, significantly complicating its differential diagnosis with intestinal diseases such as ulcerative colitis and intestinal tuberculosis.
Objective:
With the increasing application of artificial intelligence (AI) in the medical field, its utilization in clinical diagnosis has become more widespread. However, there is a lack of systematic evaluation regarding the specific efficacy of AI in identifying CD through capsule endoscopy.
Methods:
This study conducted a comprehensive search of PubMed databases, Cochrane, EMBASE, and Web of Science up to May 21, 2024, to collect relevant literature. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to rigorously assess the quality of included studies, and detailed information on study characteristics and AI algorithms was extracted. A bivariate mixed-effects model was employed to synthesize and analyze the sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). Additionally, meta-regression and subgroup analyses were conducted to delve into the potential sources of heterogeneity.
Results:
Ultimately, eight studies encompassing 11 distinct AI models were included in this meta-analysis. The overall area under the curve (AUC) for AI in identifying CD through capsule endoscopy (CE) was 99% (95% CI, 100%-0.00), indicating high diagnostic accuracy. Specifically, the pooled sensitivity was 94% (95% CI, 93%-96%), specificity was 97% (95% CI, 95%-98%), positive likelihood ratio (PLR) was 32.7 (95% CI, 19.9-53.6), negative likelihood ratio (NLR) was 6% (95% CI, 4%-7%), and diagnostic odds ratio (DOR) reached 576 (95% CI, 295-1127). Meta-regression analysis further revealed that AI algorithm type, study population size, and study design might be key sources of heterogeneity.
Conclusions:
This study demonstrates the significant potential of AI technology in assisting endoscopists in detecting and identifying CD patients through capsule endoscopy. However, given the limitations and heterogeneity of current research, more high-quality, large-sample studies are needed to comprehensively and thoroughly evaluate the practical application value of AI in CD diagnosis, thereby promoting its widespread adoption and optimization in clinical practice.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.