Previously submitted to: JMIR Cardio (no longer under consideration since Jan 09, 2024)
Date Submitted: Aug 14, 2023
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Using 3D Convolutional Neural Network to Detect Wall Motion Abnormalities on Echocardiography
ABSTRACT
Background:
Transthoracic echocardiography is the most important modality to evaluate wall motion abnormalities (WMAs) caused by significant stenosis of coronary artery. However, the assessment of WMAs is mainly based on visual interpretation of echocardiographers, which is subjective and affected by clinical experience of operators. An objective, accurate and automatic method is needed.
Objective:
3D convolutional neural network (CNN), a deep learning method, has been widely used to analyze video data and achieved good results, therefore, we trained a 3D CNN to automatically detect WMAs on echocardiography.
Methods:
This study was consisted of two parts: (1) Left Ventricular Chamber (LVC) segmentation and End Diastole (ED) identification; (2) WMAs detection and Vessel identification. We collected echocardiography videos from 2019 to 2021 in our hospital to train and validate the deep learning model and also obtained data from the other two hospitals for external validation. We introduced Unet to segment LVC, and calculate the area of LVC to identify the frames of EDs (maximum area). Then, we extracted the frames between EDs to train 3D CNN to detect WMAs and identify the vessels that may cause WMAs.
Results:
We collected 311 videos (over 6000 images) to train LVC segmentation network and 1557 videos to construct WMAs detection model. Moreover, we used 657 videos to train and test vessel identification model. We also collected 171 videos from other hospital to perform external validation. As for LVC segmentation, the Unet achieved average Dice=0.92 and average IoU=0.86. We using 30 videos (with ECG signal) to test the ability of ED detection module. The network identified 89 ED of 92 ED, and the error between identified EDs and standard EDs (peaks of QRS wave) was 1.7±1.4 frames. In terms of WMAs detection model, the 3D CNN achieved promising results with AUC= 0.97 (95% CI 0.87-0.99) and corresponding accuracy, sensitivity and specificity were 92.2%, 95% (95% CI 75.1%-99.9%) and 90.3% (95% CI 74.2%-98%), respectively. The AUC of identifying significant stenosis of left anterior descending was 0.73. The results of WMAs detection on external validation were 0.76 (95% CI 0.63-0.87) for AUC and 78.9% for accuracy.
Conclusions:
3D CNN was capable of detecting WMAs and achieved promising results on internal validation. As for external validating, the network showed that it can also detect WMAs.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.