Maintenance Notice

Due to necessary scheduled maintenance, the JMIR Publications website will be unavailable from Wednesday, July 01, 2020 at 8:00 PM to 10:00 PM EST. We apologize in advance for any inconvenience this may cause you.

Who will be affected?

Previously submitted to: JMIR mHealth and uHealth (no longer under consideration since May 17, 2022)

Date Submitted: Jan 22, 2022
Open Peer Review Period: Jan 22, 2022 - Mar 19, 2022
(closed for review but you can still tweet)

NOTE: This is an unreviewed Preprint

Warning: This is a unreviewed preprint (What is a preprint?). Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn (a note "no longer under consideration" will appear above).

Peer review me: Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period (in this case, a "Peer Review Me" button to sign up as reviewer is displayed above). All preprints currently open for review are listed here. Outside of the formal open peer-review period we encourage you to tweet about the preprint.

Citation: Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author).

Final version: If our system detects a final peer-reviewed "version of record" (VoR) published in any journal, a link to that VoR will appear below. Readers are then encourage to cite the VoR instead of this preprint.

Settings: If you are the author, you can login and change the preprint display settings, but the preprint URL/DOI is supposed to be stable and citable, so it should not be removed once posted.

Submit: To post your own preprint, simply submit to any JMIR journal, and choose the appropriate settings to expose your submitted version as preprint.

Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.

Estimation of the Heart Rate and Energy Expenditure with a Smart Bracelet during Different Intensities of Exercise: A Reliability and Validity Study

  • Guoxin Ni; 
  • Yihui Cai; 
  • Zi Wang; 
  • Weiya Kong; 
  • Jiayao Jiang; 
  • Leyi Feng; 
  • Ruobing Zhao; 
  • Dongxue Wang

ABSTRACT

Background:

Wrist-worn wearables have become an increasingly popular way to assess exercise intensity and energy expenditure (EE) in health care and various other settings. However, there is still few research on the validity and reliability of wrist-worn wearables in monitoring exercise parameters at different intensities by people with different levels of physical activity.

Objective:

This study assessed the validity and reliability of the Mio Smart Bracelet (Lexin Mio Band 1) in measuring the heart rate (HR) and EE with different physical activity levels during exercise at different intensities. The second objective was to determine if wear position (i.e. dominate or nondominate hand) would cause differences in assessments.

Methods:

A total of 65 participants (N = 65; 63% female, n = 41; 37% male, n = 24) wore the Lexin smart bracelet (Mio Band 1) and its validity and reliability were assessed against two “gold standard” devices: the Polar H10 heart rate band (for HR) and the gas-analysis system (GAS, Metalyzer 3B) for EE. The participants completed one maximal oxygen uptake (VO2max) test and a running exercise test twice (10-min resting period; 6-min treadmill exercise under three intensities; 10-min recovery period). To measure test-retest reliability, intra-group correlation coefficient (ICC) were determined between the first and second treadmill test. Validity was determined by comparing the Mio with the gold standard (Polar and GAS), using mean differences, mean absolute percentage errors (MAPE), ICC and Bland-Altman analysis.

Results:

For the reliability, the HR consistency between the tests was significant (p < 0.05) in all the states except the Mio in HPAL (P < 0.05), while the EE consistency between the tests, only the right-wrist Mio showed significance in the low-physical-activity level (LPAL) population, and for the moderate-intensity exercise (MIE) and the high-intensity exercise (HIE) in the moderate-physical-activity level (MPAL) population. With regard to the validity, the MAPE between the Polar and the left- and right-wrist Mio bracelets (henceforth “left and right Mios”) ranged from 1% to 7.55%, while the MAPE between the left and right Mios ranged from 10.37% to 32.42%. The HR consistency in the LPAL, MPAL, and high-physical-activity level (HPAL) populations was significant between polar and the left and right Mios at different exercise intensities (P < 0.01), and insignificant only in HPAL group under HIE (P>0.05). As for the EE consistency, it was significant in the left and right Mios under MIE and in the right Mio under HIE in the LPAL group; in the left and right Mios under MIE or HIE, and in the right Mio during recovery in MPAL group; and in the left and right Mios under MIE in the HPAL group (P < 0.05).

Conclusions:

For HR measurement, the Lexin Mio bracelet showed good reliability and validity among people with different physical activity levels who were exercising under various intensities in a laboratory setting. However, for the estimation of the EE, the Lexin Mio bracelet showed low reliability and validity. Clinical Trial: This study was approved by the Experimental Ethics Committee for Sports Science of Beijing Sport University (registration number 2020133H). The participants were informed of the study purpose and procedures and then signed a written informed consent form before enrollment in this study.


 Citation

Please cite as:

Ni G, Cai Y, Wang Z, Kong W, Jiang J, Feng L, Zhao R, Wang D

Estimation of the Heart Rate and Energy Expenditure with a Smart Bracelet during Different Intensities of Exercise: A Reliability and Validity Study

JMIR Preprints. 22/01/2022:36726

DOI: 10.2196/preprints.36726

URL: https://preprints.jmir.org/preprint/36726

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.