Remote Health Care Monitoring Based on the Internet Transmission System of a Patient's Essential Body Functions

  • Hao-Chun Lu; 
  • Woon-Man Kung; 
  • Shuo-Tsung Chen

ABSTRACT

Background:

With Electrocardiogram (ECG) signals and Internet of things (IoT), we may have a remote observation for several clinical measurements, specifically pulse rate, intracranial pressure, respiration rate, and blood pressure, that indicate the state of a patient's essential body functions. Moreover, we can utilize ECG signals to analyze and identify various heart diseases from a distance, such as arrhythmias, myocardial damage etc. This study aims to propose an IoT-based transmission system for the state care of a patient's essential body functions. The system also protects personal privacy and reduces the carrying amount in ECG network transmission. First of all, we perform the proposed patients state steganography on the ECG signals. At the same time, we adopt the threshold-based compression to reduce the data amount of the ECG signals in patients information transmission. The recovery of the compressed ECG signal adopts cubic spline. In addition, the performance of the proposed steganography is enhanced by Particle Swarm Optimization (PSO). Experimental results verify the efficiency of the proposed method.

Objective:

In the proposed concept as shown in Fig. 3, original ECGs and patients confidential information are first combined by the proposed method (see Fig. 4 in detail) to obtain the hidden and compressed ECG. Next, the hidden and compressed ECGs are transferred to terminal equipment such as hospital server via wireless network. Finally, hospital server will extract the patients information and distribute it to different devices of doctors and nurses.

Methods:

This study proposes a time-domain algorithm to integrate threshold-based compression and PSO-based biomedical signal steganography. Because ECG has high requirements for accuracy, so we rewritten signal-to-noise ratio (SNR) and amplitude-quantization to performance index and constraint so that we obtain an optimization model to enhance ECG quality and robustness against attacks. In addition, the optimization model is solved by Particle Swarm Optimization (PSO). Accordingly, we perform amplitude-quantization steganography on each ECG signal to embed patient information. At the same time, we adopt the threshold-based compression technology to reduce the data amount of the embedded ECG signal. In addition, the hidden information can be extracted without the original ECG and the recovery of the compressed ECG signal adopts cubic spline. In experiments, we evaluate the appropriate threshold ε and embedding strength Q. The proposed method reduces the carrying amount of network transmission while preserving the original characteristics of ECG signals and protecting personal privacy.

Results:

Our method remains high quality for each hidden ECG signal or hidden and compressed ECG signal under sufficient hiding capacity 2048 bits no matter how the quantization size Q is increased.

Conclusions:

The proposed method not only protect the security of the ECG transmission but also reduce the amount of ECG transmission. Moreover, the proposed method improves the drawback that the quality of each hidden ECG signal is greatly reduced as the quantization size Q is increased. In other words, our method remains high quality for each hidden ECG signal or hidden and compressed ECG signal no matter how the quantization size Q is increased. Clinical Trial: No trial registration.


 Citation

Please cite as:

Lu HC, Kung WM, Chen ST

Remote Health Care Monitoring Based on the Internet Transmission System of a Patient's Essential Body Functions

JMIR Preprints. 06/12/2020:26298

DOI: 10.2196/preprints.26298

URL: https://preprints.jmir.org/preprint/26298

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.