Thermal analgesia, exploring the boundary between pain relief and nociception using a novel pulsed heating device

  • Charles Chabal; 
  • Peter Dunbar; 
  • Ian Painter

ABSTRACT

Background:

Humans have used heat to provide analgesia and comfort for thousands of years yet there are many aspects that remain poorly understood. There are major gaps in knowledge such as mechanism of action, optimal temperature and duration of heat. This study compared the delivery of twice the thermal energy of a previous study and examined aspects such as time of onset, analgesic effect, and duration of effect. In addition, a new safety standard and measure of thermal energy is proposed.

Objective:

The objective of this study was to examine aspects of thermal analgesia that are poorly understood in a human chronic low back pain model. These include: 1. The time on onset of thermally induced pain relief. 2. The duration of pain relief from a single 30 minute treatment session. 3. The effects of increasing the amount of thermal energy delivered on the amount and duration of pain relief. 4. Information related to skin safety associated with thermal energy delivered and information related to the pain relief nociceptive boundary.

Methods:

A randomized blinded controlled three arm trial was designed to compare the analgesic response to heat delivered via pulses at 4 pulses/minute at 45°C (N=30) versus heat delivered via pulses at 2 pulses/minute at 45°C (N=49) to steady heat at 37°C (N=51) in subjects with longstanding low back pain. Treatment lasted 30 minutes with follow-up out to four hours. The hypothesis was that the highest energy group (4 pul ses/minute) would receive improved analgesia compared to the other groups. Time of onset and duration of effect was also measured.

Results:

The primary outcome measure was pain reduction 30 minutes after the end of treatment and used the 10 point numeric pain scale. Reduction in pain was greater for the both the experimental group in the Initial Study (2 pulses per minute) and the High Energy Study group (4 pulses per minute) as compared to the control group (steady heat). The High Energy group (4 pulses per minute) reduced pain for the entire 180 minutes of post heating observation as compared to the Initial Study group (2 pulses per minute) that reduced pain for 120 minutes. The reduction in pain in the High Energy group was greater than that in the experimental group in the Initial Study but did not reach statistical significance. Both experimental groups (2 pulses per minute and 4 pulses per minute) produced significantly better analgesia when compared to the steady heat control group.

Conclusions:

High level pulsed heat 45°C at 4 pulses per minute produced significantly longer analgesia as compared to the control groups of pulsed heat 45°C at 2 pulses per minute, and steady heat at 37°C. Pain relief was rapid, with an onset of analgesia < 5 minutes. The results suggest that there is a dose relationship between thermal energy delivered and duration of analgesia with the upper limit likely defined as the analgesic nociceptive boundary. In this study that boundary was not reached offering a possibility of improved analgesia as thermal energy is increased. However, increased thermal energy requires a better standardized approach to user safety. The concept of CEM43 as a measure of thermal energy and safety is introduced. The results provide insight into the mechanisms and properties of thermal analgesia that are not well understood in a chronic low back pain model. Clinical Trial: NCT04109703


 Citation

Please cite as:

Chabal C, Dunbar P, Painter I

Thermal analgesia, exploring the boundary between pain relief and nociception using a novel pulsed heating device

JMIR Preprints. 21/08/2020:23752

DOI: 10.2196/preprints.23752

URL: https://preprints.jmir.org/preprint/23752

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.