Previously submitted to: JMIR Medical Informatics (no longer under consideration since Jan 11, 2021)
Date Submitted: Aug 8, 2020
Warning: This is an author submission that is not peer-reviewed or edited. Preprints - unless they show as "accepted" - should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
A method for automatic detection of atrial fibrillation: based on CNN combined with BLSTM
ABSTRACT
Background:
Atrial fibrillation (AF) is the most common arrhythmia harmful to human health. The morbidity and mortality of AF increase with age. However, due to its small amplitude and short duration, as well as its complexity and nonlinearity, it is very difficult to carry out accurate analysis only through expert experience. Therefore, the automatic detection of AF becomes extremely important.
Objective:
The purpose of this paper is to develop a method of automatic detection of AF, more accurate and efficient automatic detection of the occurrence of AF.
Methods:
In this paper, a deep learning model consisting of a convolutional neural network (CNN) and a bi-directional long short-term memory (BLSTM) network is proposed to detect AF automatically. The model is mainly composed of six convolutional layers, three pooling layers, a BLSTM layer and a fully connected layer. In addition, the data of MIT-BIH AFDB database is divided into different lengths of ECG segments, which are used as input to the network to verify the effect of different lengths of ECG segments on the final result.
Results:
The method proposed also achieved excellent results on ECG signals of 1 second. Most importantly, our proposed method achieved the best performances on ECG signals of 10 seconds, with an accuracy of 99.57%,a sensitivity of 99.65%,and a specificity of 99.49%.
Conclusions:
This method requires no complex pretreatment and retains the characteristics of the original ECG to the greatest extent. Compared with the existing studies, the proposed method has higher accuracy and provides an effective solution for the automatic detection of AF.
Citation
Request queued. Please wait while the file is being generated. It may take some time.
Copyright
© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.