ABSTRACT

Background:

The use of medical devices is rapidly expanding. Despite this, there is a huge gap in the literature surrounding the use of devices in healthcare and the adverse events occurring. Given that these errors can be life-threatening, it is imperative to have a thorough understanding of the problem in order to improve patient safety.

Objective:

To conduct a Rapid Review to identify the frequency, types and causes of medical device-related errors which are reported in published peer-reviewed literature.

Methods:

Following PRISMA guidelines, a literature search strategy was developed. Databases searched until 23 February 2018 included Pubmed, International Pharmaceutical Abstracts and Cinahl. Articles were included if they: defined medical devices, reported the frequency, causes and types of errors, were published in peer-reviewed literature. Articles were screened and discussed by two authors.

Results:

Database searching yielded 7,559 unduplicated articles. After two rounds of screening, 24 articles were included in the Review. Device types included cochlear implants, defibrillator leads, anaesthetic & intensive care devices, surgical equipment, automated external defibrillators, radiation oncology devices, ambulance stretchers, breast pumps, cardiovascular devices, orthopaedic devices, and patient controlled analgesia devices. The frequency of errors was 3.83-33.0%. The most common causes were user error, malfunction and design error.

Conclusions:

This Review identified a range of device types associated with errors. The frequency of errors was lower than published literature. User error was confirmed as a leading cause, alongside malfunction and design error. Future research should examine near-miss events and expand the device types studied.


 Citation

Please cite as:

Anderson E, Poon S, Penm J

The frequency, types and causes of medical device-related errors reported in the literature: a Rapid Review

JMIR Preprints. 17/03/2020:18775

DOI: 10.2196/preprints.18775

URL: https://preprints.jmir.org/preprint/18775

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.