A system for automated motor function assessment in stroke patients using motion sensing technology

  • Bo Sheng; 
  • Xiangbin Wang; 
  • Meijin Hou; 
  • Jia Huang; 
  • Shuping Xiong; 
  • Yanxin Zhang

ABSTRACT

Background:

Upper-limb motor function assessment for stroke patients is essential for planning interventions to maximise function and independence.

Objective:

The general aim of this study is to realize the automated assessment of upper-limb motor function after stroke by using motion sensing technology and machine learning algorithms.

Methods:

The proposed system contained two subsystems. A motion tracking subsystem was developed for measuring the kinematic data of participants through Kinect V2. A motor function assessment subsystem was developed to realize the automated assessment based on a feed-forward neural network (FFNN)-based assessment model. The assessment model was developed by thirty-two kinematic metrics calculated from the gathered data. In addition, five metrics with ten-fold cross-validation were used for performance evaluation (accuracy, F1-score, specificity, sensitivity, and AUC), and the developed FFNN-based model was compared with ten well-known machine learning algorithm-based models.

Results:

26 participants between 20 to 79 years of age, living in the Fuzhou city (Fujian) were recruited from October 2018 to January 2019. A total of 2400 patterns were calculated as the dataset after data processing. The experimental results showed that the proposed system presented satisfactory performance: overall accuracy ranged from 0.87 to 0.96, and F1-score ranged from 0.83 to 0.93. The FFNN-based assessment model presented promising comprehensive performance: it ranked top two for all tasks in the metrics of overall accuracy and F1-score.

Conclusions:

The proposed system presents a promising method for automated assessment of upper-limb motor function in stroke patients. The system could be implemented in clinical applications as a cheap and portable assessment tool and provide decision support for physiotherapists as well.


 Citation

Please cite as:

Sheng B, Wang X, Hou M, Huang J, Xiong S, Zhang Y

A system for automated motor function assessment in stroke patients using motion sensing technology

JMIR Preprints. 18/10/2019:16731

DOI: 10.2196/preprints.16731

URL: https://preprints.jmir.org/preprint/16731

Download PDF


Request queued. Please wait while the file is being generated. It may take some time.

© The authors. All rights reserved. This is a privileged document currently under peer-review/community review (or an accepted/rejected manuscript). Authors have provided JMIR Publications with an exclusive license to publish this preprint on it's website for review and ahead-of-print citation purposes only. While the final peer-reviewed paper may be licensed under a cc-by license on publication, at this stage authors and publisher expressively prohibit redistribution of this draft paper other than for review purposes.